Error Mode Summary
Display Error Code
tE1
Thermistor Error 1
tE2
Thermistor Error 2
tE4
Thermistor Error 4
dE
Door Switch Error
PS
Power Supply Error
EE
EEPROM Error
Add
Steam Water Level Error
Water
E5
Water Pump Error
LG Electronics Training Center, LGEAI, U.S.A.
Notes
LG Electronics Training Center, LGEAI, U.S.A.
•
Temp Thermistor (Open)
•
Temp Thermistor (Shorted)
•
Only displayed in Test Mode
•
Steam Thermistor Error (Replace SG)
•
Only displayed in Test Mode
•
Neutral Tap not present
•
L1, L2, or N not present or wired to
wrong location
•
Only displayed in Test Mode
•
High Water Level not reached within 60
seconds
•
Only displayed in Test Mode
•
Pump AD Valve value < 10
•
Replace Water Pump
87
88