3. Execute the adjustment in the following service mode.
• Auto adjustment of the fold-enhancing control values:
SORTER > FUNCTION > PF-MTR

Handling When Replacing the Upper Cover Unit

■ Preparation/Procedure
"Removing the Upper Cover Unit" on page 47
■ Handling after Parts Replacement
1. Execute the tab length adjustment of Z-fold in the following service mode.
on page 79
• Adjustment of the tab length of Z-fold:
SORTER> ADJUST> PF-T-EDG

Adjustment When Replacing the Fold-enhancing Unit

■ Preparation/Procedure
"Removing the Fold-enhancing Unit" on page 48
■ Adjustment Procedure
CAUTION:
When the new Fold-enhancing Unit is installed, execute the following adjustment.
1. Install the new Fold-enhancing Unit.
2. Close the Upper Cover.
3. Move the Holder [1] to the rear side. Check that the distance [A] between the frame and the fold-enhancing holder
is within the standard.
[A] = 6.0 ± 0.3 mm
[A]
" Adjustment of the Tab Length of Z-fold"
81