7.2.3

Connect the AC wires - Terra 60

7.2.4

Connect and seal the AC wires - Terra 360

E
X
L1 L2 L3
N
L1 L2 L3
• Connect the AC cables to the main switch terminals.
Respect the components sequence shown in the figure.
• Tighten the fasteners respeting following torque:
Cross section (mm
L1 (Brown) 150
L2 (Black)
150
X
L3 (Grey)
150
N (Blue)
150
NOTE
Make sure that the cable glands on each
X
cable are correctly sealed.
• Connect the AC cables to the main switch terminals.
• Tighten the fasteners respeting following torque:
Cross section (mm
L1 (Brown) 2 x 240
L2 (Black)
2 x 240
L3 (Grey)
2 x 240
• Pull the cable ties on each AC cable.
)
Torque (Nm)
2
30...44
C
30...44
30...44
30...44
)
Torque (Nm)
2
50...75
50...75
50...75