12-3.SCOPE OF IP65 APPLICATION
With the power supply terminal box as an outline, it shall apply to the portions excluding the
cable gland part (dust and water ingress routes illustrated in Fig. 12-1.)
*A customer is requested to examine the cable gland part during the prototype test, and
confirm the protection rating.
*Use the cable gland with the following specifications.
IP codes
Heat resistant temperature
Plug cover fixing screw (4 places)
(Screw tightening torque = 2 N・m)
Cable gland
Cable
Out of scope: Ingress of
dust and water
IP66 or IP68 (pressure resistance 0.1 MPa or higher)
120
Figure 12-1.Power Supply Terminal Box (View from A)
13
or higher
Plug cover
Connector block
Sealed type power terminal
Power supply
terminal box
Gasket
Protection
cover