Download Print this page

LG 0CVW0-01O Manual page 34

Heat pump 380-415v + 380v r410a(50hz/60hz)

Advertisement

MULTI V Water IV
6. Electrical Characteristics
 60Hz
Model
Hz
8HP
60
10HP
60
14HP
60
20HP
60
16HP
60
18HP
60
22HP
60
24HP
60
28HP
60
30HP
60
34HP
60
40HP
60
42HP
60
44HP
60
48HP
60
50HP
60
54HP
60
60HP
60
62HP
60
64HP
60
68HP
60
70HP
60
74HP
60
80HP
60
Note
1. Voltage supplied to the unit terminals should be within the minimum and maximum range.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MSC means the Max. current during the starting of compressor.
4. MSC and RLA are measured as the compressor only test condition.
5. OFM are measured as the outdoor unit test condition.
6. TOCA means the total over current value of each outdoor unit.
7. Select the wire size based on the larger value among MCA or TOCA.
8. MFA is used to select the circuit breaker and ground fault circuit interrupter, and all
installation site must requirement attachment of an earth leakage breaker.[circuit breaker
type is ELCB (Earth Leakage Circuit Breaker)].
9. Select the electrical equipment of combination unit according to the electrical characteristics
of individual unit.
24
Heat Pump
Unit
Volts
Voltage-range
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
380
Min.:342,Max:418
Power supply
MCA
MFA
TOCA
17.9
25
24
18.6
25
24
20.0
25
24
29.0
35
32
35.8
50
48
36.5
50
48
37.9
50
48
38.6
50
48
40.0
50
48
47.6
60
56
49.0
60
56
58.0
70
64
66.9
85
80
67.6
85
80
69.0
85
80
76.6
95
88
78.0
95
88
87.0
105
96
95.9
120
112
96.6
120
112
98.0
120
112
105.6
130
120
107.0
130
120
116.0
140
128
Outside Units
Comp
MSC
RLA(Cooling)
RLA(Heating)
-
6.31
-
8.32
-
12.81
-
18.3
-
12.61
-
14.62
-
19.11
-
21.12
-
25.62
-
26.61
-
31.11
-
36.59
-
37.41
-
39.42
-
43.91
-
44.91
-
49.40
-
54.89
-
55.71
-
57.72
-
62.21
-
63.21
-
67.70
-
73.19
Symbols
MCA : Minimum Circuit Amperes (A)
TOCA : Total Over Current Amperes (A)
MFA : Maximum Fuse Amperes (A)
MSC : Maximum Starting Current (A)
RLA : Rated Load Amperes (A)
OFM : Outdoor Fan Motor
kW : Fan Motor rated output (kW)
FLA : Full Load Amperes (A)
6.86
8.72
13.35
19.07
13.72
15.59
20.21
22.07
26.69
27.79
32.41
38.13
39.27
41.14
45.76
46.85
51.48
57.20
58.34
60.20
64.83
65.92
70.54
76.26

Advertisement