Toshiba VFNC3-2001P Instruction Manual page 107

Industrial inverter
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc
Set frequency speed reach signal
Between OUT-NO terminals
Set frequency speed reach signal:
Inverted
6.1.3
Output of set frequency speed reach signal
 : Speed reach setting frequency
 : Speed reach detection band
• Function
When the output frequency becomes equal to the frequency set by ± , an ON or OFF
signal is generated.
Parameter setting of frequency and detection band
Title
Speed reach setting frequency

Speed reach detection band

Parameter setting of output terminal selection
Title
Output terminal

selection 1A (OUT)
Note: Set  to output to FLA-FLC-FLB terminals.
Output frequency [Hz]
Designated frequency + 
Designated frequency
Designated frequency − 
0
Function
Function
Adjustment range
0-255
(See 11.7.)
F-3
Adjustment range
0.0 ∼  (Hz)
0.0 ∼  (Hz)
Setting value
8: RCHF (Set frequency attainment
signal), or
9: RCHFN (Inversion of RCHF)
E6581595
Time [s]
ON
OFF
ON
OFF
6
Default setting
0.0
2.5