5.6
Meter setting and adjustment
: Meter selection
: Meter adjustment
For details, see 3.4.
5.7
Forward/reverse run selection (Panel keypad)
: Forward/reverse run selection (Panel keypad)
• Function
Program the direction of rotation of the motor when the running and stopping are made using the RUN
key and STOP key on the operation panel.
Valid when (command mode) is set to (operation panel).
Parameter setting
Title
Forward/reverse run selection
(Panel keypad)
When is set to , the standard monitor is displayed, pressing the FWD/REV key on the extension
panel (option RKP007Z) changes the direction of rotation from reverse to forward after displaying the
message .
Pressing the FWD/REV key again changes the direction of rotation from reverse to forward after
displaying the message .
Check the direction of rotation on the status monitor. For monitoring, see8.1
: Forward run
: Reverse run
When the F and R terminals are used for switching between forward and reverse rotation from the
terminal board, the forward/reverse run selection parameter is rendered invalid.
Short across the F-CC terminals: forward rotation
Short across the R-CC terminals: reverse rotation.
The inverter was factory-configured by default so that shorting terminals F-CC and terminals R-CC
simultaneously would cause the motor to slow down to a stop.
Using the parameter , however, you can select between forward run and reverse run.
Function
0: Forward run
1: Reverse run
2: Forward run (F/R switching on
remote keypad)
3: Reverse run (F/R switching on
remote keypad)
E-13
Adjustment range
E6581595
5
Default setting
0