Panasonic AccuPulse QP Low Noise Series Operating Instructions Manual page 14

Battery operated tool, cordless mechanical pulse driver / cordless mechanical pulse wrench
Table of Contents

Advertisement

Available languages

Available languages

[Fig.20]
How to set
EN
[Step 1]
Select Torque Setting Stage (1-40)
Torque Setting Stage:
Select referring to index chart
[Fig. 22]
Snug Tight Detection setting: L1
Select Flush Detection Level (L1-L7 / Use only when final torque can't be increased by
[Step 2]
Torque Setting Stage change)
* Increase Flush Detection Level one by one. There is a risk of over torque when Flush Detection Level is increased.
Torque Setting Stage:
* Select referring to index chart
Snug Tight Detection setting:
Change from L1 to L2
* Please reset Torque Setting Stage if it's
increased in Step1.
[Step 3]
Fine-tune Torque Setting Stage to meet target torque and complete setting
Trial fastening
Check torque
Not OK
Change Torque
Setting Stage
Trial fastening
Check torque
Not OK
Change Snug Tight
Detection setting
L2→L3~L7
‒ 14 ‒
Final torque meets target torque
OK
Even though changing Torque Setting Stage,
final torque can't be increased.
(Fastener doesn't seat correctly)
Not OK
Final torque is above lower tolerance limit
OK
Flush!
Final torque can't be increased.
(Fastener doesn't seat correctly)
Setting
complete
Move to Step 2
Move to Step 3

Advertisement

Table of Contents
loading

Table of Contents