Panasonic AccuPulse QP Low Noise Series Operating Instructions Manual page 23

Battery operated tool, cordless mechanical pulse driver / cordless mechanical pulse wrench
Table of Contents

Advertisement

Available languages

Available languages

[EYFLF]
Setting the undetect time
To set the time to undetect the function of
"snug point detection level" from the start
tightening, do as follows.
1. Set the tool to the configuration mode.
(See page 19.)
2. Press button A three times.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: J0 flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.26]
3. Press
and
change the time.
Operation
Display
4. Press the OK button to accept the new
setting.
[EYFLF]
Setting the impact speed
corresponding to the length of the
socket used
Due to the specifications of this product, this
item can be set, but the impact speed will not
be changed.
1. Set the tool to the configuration mode.
(See page 19.)
2. Press button D three times.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: h0 flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.27]
3. Press
and
change the value.
buttons as required to
Seconds
30
3
1
0.1
J0
OFF
buttons as required to
Display
h0
h1
h2
4. Press the OK button to accept the new
setting.
[EYFLF]
Setting use interval
Use interval is set to prevent the screwdriver
from continuing its operation when the tool is
automatically stopped due to the implementa-
tion of the torque correction feature. This set-
ting is valid even when the switch is off.
1. Set the tool to the configuration mode.
(See page 19.)
2. Press button D twice.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: U flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.28]
3. Press
and
time.
Operation
4. Press the OK button to accept the new
setting.
• The control panel stops flashing and
lights up to display the torque clutch
settings.
‒ 23 ‒
Impact Speed Standard
Standard socket
(high speed)
Up to 150 mm socket
(medium speed)
Up to 250 mm socket
(low speed)
as required to change the
Display
Seconds
U9
3
U8
2.5
U7
2
U6
1.5
U5
1.2
U4
1
U3
0.7
U2
0.5
U1
0.3
U0
0.1
U
OFF
EN

Advertisement

Table of Contents
loading