Code
Function Name
A094
Select method to switch to Acc2/Dec2 profile
A294
Select method to switch to Acc2/Dec2, 2nd motor
A095
Acc1 to Acc2 frequency transition point
A295
Acc1 to Acc2 frequency transition point, 2nd motor
A096
Dec1 to Dec2 frequency transition point
A296
Dec1 to Dec2 frequency transition point, 2nd motor
A097
Acceleration curve selection
A098
Deceleration curve selection
A101
OI-L input active range start frequency
A102
OI-L input active range end frequency
A103
OI-L input active range start current
A104
OI-L input active range end current
A105
OI-L input start frequency enable
A111
O2-L input active range start frequency
A112
O2-L input active range end frequency
A113
O2-L input active range start voltage
A114
O2-L input active range end voltage
A131
Acceleration curve constants setting
A132
Deceleration curve constants setting
A141
Operation-target frequency selection 1
A142
Operation-target frequency selection 2
A143
Operator selection
A145
Frequency to be added
A146
Sign of the frequency to be added
A150
EL-S-curve acceleration ratio 1
A151
EL-S-curve acceleration ratio 2
A152
EL-S-curve deceleration ratio 1
A153
EL-S-curve deceleration ratio 2
(*1) 4000HF:0.00 to 99.99, 100.0 to 120.0(Hz) (*2) 4000HF: -120. to -100., -99.9 to 0.00 to 99.99, 100.0 to 120.0(Hz)
●B GROUP: FINE TUNING FUNCTIONS
Code
Function Name
b001
Selection of restart mode
b002
Allowable under-voltage power failure time
b003
Retry wait time before motor restart
Instantaneous power failure/under-voltage
b004
trip alarm enable
Number of restarts on power
b005
failure/under-voltage trip events
b006
Phase loss detection enable
b007
Restart frequency threshold
b008
Selection of retry after tripping
b009
Selection of retry after undervoltage
Selection of retry count after overvoltage
b010
or overcurrent
b011
Retry wait time after tripping
Electronic thermal setting (calculated within
b012
the inverter from current output)
Electronic thermal setting (calculated within
b212
the inverter from current output), 2nd motor
Electronic thermal setting (calculated within
b312
the inverter from current output), 3rd motor
b013
Electronic thermal characteristic
b213
Electronic thermal characteristic, 2nd motor
b313
Electronic thermal characteristic, 3rd motor
b015
Free-setting electronic thermal frequency (1)
b016
Free-setting electronic thermal current (1)
b017
Free-setting electronic thermal frequency (2)
b018
Free-setting electronic thermal current (2)
b019
Free-setting electronic thermal frequency (3)
b020
Free-setting electronic thermal current (3)
b021
Overload restriction operation mode
b022
Overload restriction setting
b023
Deceleration rate at overload restriction
b024
Overload restriction operation mode (2)
b025
Overload restriction setting (2)
b026
Deceleration rate at overload restriction (2)
b027
Overcurrent suppression enable
(*1) 4000HF:5.0 (*2)4000HF: 0.00 to 99.99, 100.0 to 120.0(Hz) (*3)4000HF:0. to 120.(Hz)
Monitored data or setting
00 (switching by 2CH terminal), 01 (switching by setting),
02 (switching only when rotation is reversed)
00 (switching by 2CH terminal), 01 (switching by setting),
02 (switching only when rotation is reversed)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)
00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0. to "[OI]-[L] input active range end current" (%)
"[OI]-[L] input active range start current" to 100. (%)
00 (external start frequency), 1 (0 Hz)
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
-100. to 02 end-frequency rate (%)
"02 start-frequency rate" to 100. (%)
01 (smallest swelling) to 10 (largest swelling)
01 (smallest swelling) to 10 (largest swelling)
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via OI),
04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string frequency input)
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via OI),
04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string frequency input)
00 (addition: A141 + A142), 01 (subtraction: A141 - A142), 02 (multiplication: A141 x A142)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
00 (frequency command + A145), 01 (frequency command - A145)
0. to 50. (%)
0. to 50. (%)
0. to 50. (%)
0. to 50. (%)
Monitored data or setting
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03 (tripping after
deceleration and stopping with matching frequency), 04 (restarting with active matching frequency)
0.3 to 25.0 (s)
0.3 to 100.0 (s)
00 (disabling), 01 (enabling), 02 (disabling during stopping and decelerating to stop)
00 (16 times), 01 (unlimited)
00 (disabling), 01 (enabling)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03 (tripping after
deceleration and stopping with matching frequency), 04 (restarting with active matching frequency)
00 (16 times), 01 (unlimited)
1 to 3 (times)
0.3 to 100.0 (s)
0.20 x "rated current" to 1.00 x "rated current" (A)
0.20 x "rated current" to 1.00 x "rated current" (A)
0.20 x "rated current" to 1.00 x "rated current" (A)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
0. to 400. (Hz) (*3)
0.00 to rated current (A)
0. to 400. (Hz) (*3)
0.00 to rated current (A)
0. to 400. (Hz) (*3)
0.00 to rated current (A)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling during
constant speed), 03 (enabling during acceleration and deceleration (increasing the speed
during regeneration))
SJ700: 0.20 x "rated current" to 2.00 x "rated current" (A) < 75kW and over:0.20 x 1.80 >
L700: 0.20 x "rated current" to 1.50 x "rated current" (A)
0.10 to 30.00 (s)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling during
constant speed), 03 (enabling during acceleration and deceleration (increasing the speed
during regeneration))
SJ700: 0.20 x "rated current" to 2.00 x "rated current" (A) < 75kW and over:0.20 x 1.80 >
L700: 0.20 x "rated current" to 1.50 x "rated current" (A)
0.10 to 30.00 (s)
00 (disabling), 01 (enabling)
×
[◯= Allowed
= Not permitted]
Default Setting
Setting
SJ700
during operation
L700
(allowed or not)
-FE(CE) -FU(UL)
-F(JP)
00
00
00
00
×
00
00
×
00
00
0.00
0.00
0.00
×
0.00
0.00
0.00
0.00
0.00
×
0.00
0.00
0.00
0.00
×
×
0.00
0.00
0.00
0.00
00
00
×
00
00
00
00
00
×
00
0.00
0.00
0.00
0.00
×
0.00
0.00
0.00
0.00
×
20.
20.
20.
20.
×
100.
100.
×
100.
100.
00
00
00
×
00
0.00
0.00
0.00
0.00
×
0.00
0.00
0.00
0.00
×
-100.
-100.
-100.
-100.
×
100.
100.
×
100.
100.
02
02
02
×
02
02
02
02
02
×
02
02
02
02
×
03
03
×
03
03
00
00
00
00
×
0.00
0.00
0.00
0.00
×
00
00
00
00
×
25.
25.
×
25.
25.
25.
25.
×
25.
25.
25.
25.
25.
25.
×
25.
25.
25.
25.
×
×
[◯= Allowed
= Not permitted]
Default Setting
Setting
SJ700
during operation
L700
(allowed or not)
-FE(CE) -FU(UL)
-F(JP)
×
00
00
00
00
×
1.0
1.0
1.0
1.0
1.0(*1)
1.0(*1)
1.0
×
1.0(*1)
00
00
00
00
×
×
00
00
00
00
00
00
×
00
00
0.00
0.00
0.00
0.00
×
×
00
00
00
00
×
00
00
00
00
3
3
3
3
×
×
1.0(*1)
1.0(*1)
1.0(*1)
1.0
×
Rated current of
×
inverterx 1..0
×
×
01
01
00
01
×
01
01
00
01
01
01
00
01
×
0.
0.
0.
0.
×
×
0.0
0.0
0.0
0.0
×
0.
0.
0.
0.
×
0.0
0.0
0.0
0.0
0.
0.
0.
0.
×
0.0
0.0
0.0
0.0
×
×
01
01
01
01
Rated
×
Rated current x 1.50
current
x 1.20
×
1.00
1.00
1.00
1.00
×
01
01
01
01
Rated
×
Rated current x 1.50
current
x 1.20
×
1.00
1.00
1.00
1.00
×
01
01
01
01
Change
during operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
Change
during operation
(allowed or not)
16