Advertisement

Code
Function Name
b028
Active frequency matching, scan start frequency
b029
Active frequency matching, scan-time constant
b030
Active frequency matching, restart frequency select
b031
Software lock mode selection
b034
RUN/ power-on warning time
b035
Rotational direction restriction
b036
Reduced voltage start selection
b037
Function code display restriction
b038
Initial-screen selection
b039
Automatic user-parameter setting function enable
b040
Torque limit selection
Torque limit(1)
b041
(Forward-driving in 4-quadrant mode)
Torque limit(2)
b042
(Reverse-regenerating in 4-quadrant mode)
Torque limit(3)
b043
(Reverse-driving in 4-quadrant mode)
Torque limit(4)
b044
(Forward-regenerating in 4-quadrant mode)
b045
Torque limit LADSTOP enable
b046
Reverse RUN protection enable
b050
Controlled deceleration and stop on power loss
b051
DC bus voltage trigger level during power loss
b052
Over-voltage threshold during power loss
b053
Deceleration time setting during power loss
b054
Initial output frequency decrease during power loss
b055
Proportional gain setting for nonstop operation at power loss
b056
Integral time setting for nonstop operation at power loss
b060
Maximum-limit level of window comparators O
b061
Minimum-limit level of window comparators O
b062
Hysteresis width of window comparators O
b063
Maximum-limit level of window comparators OI
b064
Minimum-limit level of window comparators OI
b065
Hysteresis width of window comparators OI
b066
Maximum-limit level of window comparators OI
b067
Minimum-limit level of window comparators O/OI/O2
b068
Hysteresis width of window comparators O/OI/O2
b070
Operation level at O disconnection
b071
Operation level at OI disconnection
b072
Operation level at O2 disconnection
b078
Cumulative input power data clearance
b079
Cumulative input power display gain setting
b082
Start frequency adjustment
b083
Carrier frequency setting
b084
Initialization mode (parameters or trip history)
b085
Country code for initialization
b086
Frequency scaling conversion factor
b087
STOP key enable
b088
Restart mode after FRS
b089
Automatic carrier frequency reduction
b090
Dynamic braking usage ratio
b091
Stop mode selection
b092
Cooling fan control
b095
Dynamic braking control
b096
Dynamic braking activation level
b098
Thermistor for thermal protection control
b099
Thermal protection level setting
b100
Free-setting V/f frequency (1)
b101
Free-setting V/f voltage (1)
b102
Free-setting V/f frequency (2)
b103
Free-setting V/f voltage (2)
b104
Free-setting V/f frequency (3)
b105
Free-setting V/f voltage (3)
b106
Free-setting V/f frequency (4)
b107
Free-setting V/f voltage (4)
b108
Free-setting V/f frequency (5)
b109
Free-setting V/f voltage (5)
b110
Free-setting V/f frequency (6)
b111
Free-setting V/f voltage (6)
(*1) "Over current protection" , " Overload restriction" , "Over current limiting" and "Electronic thermal protection" might operate from the set value when "Carrier
frequency setting" is used with less than 2kHz by a low value. Please set to 2kHz or more and use the setting of "Carrier frequency setting" for such a situation.
17
(*2) 1850HF,2200HF and 3150HF:2.1, 4000HF:1.9
Monitored data or setting
SJ700: 0.20 x "rated current" to 2.00 x "rated current" (A) < 75kW and over:0.20 x 1.50 >
L700: 0.20 x "rated current" to 1.50 x "rated current" (A)
0.10 to 30.00 (s)
00 (frequency at the last shutoff), 01 (maximum frequency), 02 (set frequency)
00 (disabling change of data other than "b031" when SFT is on), 01 (disabling change
of data other than "b031" and frequency settings when SFT is on), 02 (disabling change
of data other than "b031"), 03 (disabling change of data other than "b031" and
frequency settings), 10 (enabling data changes during operation)
0. to 9999. (0 to 99990), 1000 to 6553 (10000 to 655300) (hr)
00 (enabling both forward and reverse rotations), 01 (enabling only forward rotation),
02 (enabling only reverse rotation)
0 (minimum reduced voltage start time) to 255 (maximum reduced voltage start time)
00 (full display), 01 (function-specific display), 02 (user setting), 03 (data comparison
display), 04 (basic display)
00 (screen displayed when the STR key was pressed last), 01 (d001), 02 (d002),
03 (d003), 04 (d007), 05 (F001)
00 (disabling), 01 (enabling)
00 (quadrant-specific setting), 01 (switching by terminal), 02 (analog input), 03 (option 1),
04 (option 2)
SJ700: 0. to 200. (%), no (disabling torque limitation) < 75kW and over:0. to 180.>
L700: 0. to 150.(%), no (disabling torque limitation)
SJ700: 0. to 200. (%), no (disabling torque limitation) < 75kW and over:0. to 180.>
L700: 0. to 150.(%), no (disabling torque limitation)
SJ700: 0. to 200. (%), no (disabling torque limitation) < 75kW and over:0. to 180.>
L700: 0. to 150.(%), no (disabling torque limitation)
SJ700: 0. to 200. (%), no (disabling torque limitation) < 75kW and over:0. to 180.>
L700: 0. to 150.(%), no (disabling torque limitation)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
0.0 to 999.9, 1000. (V)
0.0 to 999.9, 1000. (V)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.00 to 10.00 (Hz)
0.00 to 2.55
0.0 to 9.999 /10.00 to 65.55
0. to 100. (lower limit : b061 + b062*2) (%)
0. to 100. (lower limit : b060 - b062*2) (%)
0. to 10. (lower limit : b061 - b062 / 2) (%)
0. to 100. (lower limit : b064 + b066*2) (%)
0. to 100. (lower limit : b063 - b066*2) (%)
0. to 10. (lower limit : b063 - b064 / 2) (%)
-100. to 100. (lower limit : b067 + b068*2) (%)
-100. to 100. (lower limit : b066 - b068*2) (%)
0. to 10. (lower limit : b066 - b067 / 2) (%)
0 to 100 (%) or "no" (ignore)
0 to 100 (%) or "no" (ignore)
0 to 100 (%) or "no" (ignore)
Clearance by setting "01" and pressing the STR key
1. to 1000.
0.10 to 9.99 (Hz)
SJ700: 0.5 to 15.0(kHz) <75 to 132kW:0.5 to 10.0/185kW and over:0.5 to 3.0>
L700: 0.5 to 12.0 (kHz) <90kW and over:0.5 to 8.0.>
00 (clearing the trip history), 01 (initializing the data), 02 (clearing the trip history and
initializing the data)
00 (Japan), 01 (EU), 02 (U.S.A.)
0.1 to 99.0
00 (enabling), 01 (disabling), 02 (disabling only the function to stop)
00 (starting with 0 Hz), 01 (starting with matching frequency), 02 (starting with active
matching frequency)
00: invalid, 01: valid
0.0 to 100.0 (%)
00 (deceleration until stop), 01 (free-run stop)
00 (always operating the fan), 01 (operating the fan only during inverter operation
[including 5 minutes after power-on and power-off])
00 (disabling), 01 (enabling [disabling while the motor is topped]), 02 (enabling [enabling
also while the motor is topped])
330 to 380, 660 to 760(V)
00 (disabling the thermistor), 01 (enabling the thermistor with PTC),
02 (enabling the thermistor with NTC)
0. to 9999. (Ω)
0. to "free-setting V/f frequency (2)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (3)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (4)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (5)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (6)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (7)" (Hz)
0.0 to 800.0 (V)
×
[◯= Allowed
= Not permitted]
Default Setting
Setting
SJ700
during operation
L700
(allowed or not)
-FE(CE) -FU(UL)
-F(JP)
Rated current of inverterx 1..0
×
0.50
0.50
0.50
0.50
×
×
00
00
00
00
01
×
01
01
01
0.
0.
0.
0.
×
×
00
00
00
00
×
06
06
06
06
04
04
04
04
×
×
01
01
01
01
×
00
00
00
00
00
00
00
00
×
×
150.
150.
150.
120.
×
150.
150.
150.
120.
150.
150.
150.
120.
×
×
150.
150.
150.
120.
00
00
00
00
×
00
00
00
01
×
00
00
00
00
×
×
220.0/440.0
220.0/440.0
220.0/440.0
220.0/440.0
×
360.0/720.0
360.0/720.0
360.0/720.0
360.0/720.0
×
1.00
1.00
1.00
1.00
0.00
0.00
0.00
0.00
×
0.20
0.20
0.20
0.20
0.100
0.100
0.100
0.100
100
100
100
100
0
0
0
0
0
0
0
0
100
100
100
100
0
0
0
0
0
0
0
0
100
100
100
100
-100
-100
-100
-100
0
0
0
0
255(no)
255(no)
255(no)
255(no)
×
×
255(no)
255(no)
255(no)
255(no)
×
127(no)
127(no)
127(no)
127(no)
00
00
00
00
1.
1.
1.
1.
×
0.50
0.50
0.50
0.50
×
×
5.0(*2)
5.0(*2)
5.0(*2)
3.0(*1)
00
00
00
00
×
01
02
00
×
×
1.0
1.0
1.0
1.0
×
00
00
00
00
00
00
00
00
×
00
00
00
00
×
×
0.0
0.0
0.0
0.0
×
00
00
00
00
00
00
00
01
×
00
00
00
01
×
×
360/720
360/720
360/720
360/720
×
00
00
00
00
3000.
3000.
3000.
3000.
×
0.
0.
0.
0.
×
×
0.0
0.0
0.0
0.0
×
0.
0.
0.
0.
0.0
0.0
0.0
0.0
×
0.
0.
0.
0.
×
0.0
0.0
0.0
0.0
×
×
0.
0.
0.
0.
×
0.0
0.0
0.0
0.0
0.
0.
0.
0.
×
0.0
0.0
0.0
0.0
×
0.
0.
0.
0.
×
×
0.0
0.0
0.0
0.0
Change
during operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×