Code
Function Name
C147
Logical output signal 2 operator selection
C148
Logical output signal 3 selection 1
C149
Logical output signal 3 selection 2
C150
Logical output signal 3 operator selection
C151
Logical output signal 4 selection 1
C152
Logical output signal 4 selection 2
C153
Logical output signal 4 operator selection
C154
Logical output signal 5 selection 1
C155
Logical output signal 5 selection 2
C156
Logical output signal 5 operator selection
C157
Logical output signal 6 selection 1
C158
Logical output signal 6 selection 2
C159
Logical output signal 6 operator selection
C160
Input terminal response time setting 1
C161
Input terminal response time setting 2
C162
Input terminal response time setting 3
C163
Input terminal response time setting 4
C164
Input terminal response time setting 5
C165
Input terminal response time setting 6
C166
Input terminal response time setting 7
C167
Input terminal response time setting 8
C168
Input terminal response time setting FW
C169
Multistage speed/position determination time
●H GROUP: MOTOR CONSTANTS FUNCTIONS
Code
Function Name
H001
Auto-tuning Setting
H002
Motor data selection, 1st motor
H202
Motor data selection, 2nd motor
H003
Motor capacity, 1st motor
H203
Motor capacity, 2nd motor
H004
Motor poles setting, 1st motor
H204
Motor poles setting, 2nd motor
H005
Motor speed constant, 1st motor
H205
Motor speed constant, 2nd motor
H006
Motor stabilization constant, 1st motor
H206
Motor stabilization constant, 2nd motor
H306
Motor stabilization constant, 3rd motor
H020
Motor constant R1, 1st motor
H220
Motor constant R1, 2nd motor
H021
Motor constant R2, 1st motor
H221
Motor constant R2, 2nd motor
H022
Motor constant L, 1st motor
H222
Motor constant L, 2nd motor
H023
Motor constant Io
H223
Motor constant Io, 2nd motor
H024
Motor constant J
H224
Motor constant J, 2nd motor
H030
Auto constant R1, 1st motor
H230
Auto constant R1, 2nd motor
H031
Auto constant R2, 1st motor
H231
Auto constant R2, 2nd motor
H032
Auto constant L, 1st motor
H232
Auto constant L, 2nd motor
H033
Auto constant Io, 1st motor
H233
Auto constant Io, 2nd motor
H034
Auto constant J, 1st motor
H234
Auto constant J, 2nd motor
H050
PI proportional gain for 1st motor
H250
PI proportional gain for 2nd motor
H051
PI integral gain for 1st motor
H251
PI integral gain for 2nd motor
H052
P proportional gain setting for 1st motor
H252
P proportional gain setting for 2nd motor
H060
Zero LV lmit for 1st motor
H260
Zero LV lmit for 2nd motor
H061
Zero LV starting boost current for 1st motor
H261
Zero LV starting boost current for 2nd motor
H070
Terminal selection PI proportional gain setting
H071
Terminal selection PI integral gain setting
H072
Terminal selection P proportional gain setting
H073
Gain switching time
(*1)1850HF,2200HF,3150HF and 4000HF:0.1 to 999.9, 1000. to 6553.(mΩ)
(*2)1850HF,2200HF,3150HF and 4000HF:0.001 to 9.999, 10.00 to 65.53(mH)
(*3)1850HF,2200HF,3150HF and 4000HF:0.01 to 0.35, "rated current"(A)
Monitored data or setting
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×2ms)
0. to 200. (×10ms)
Monitored data or setting
00 (disabling auto-tuning), 01 (auto-tuning without rotation),
02 (auto-tuning with rotation)
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
SJ700:0.20 to 400.0 (kW)/L700:0.20 to 160(kW)
SJ700:0.20 to 400.0 (kW)/L700:0.20 to 160(kW)
2, 4, 6, 8, 10 (poles)
2, 4, 6, 8, 10 (poles)
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
0. to 255.
0. to 255.
0. to 255.
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.01 to 99.99, 100.0 to 655.3 (mH) (*2)
0.01 to 99.99, 100.0 to 655.3 (mH) (*2)
0.01 to 99.99, 100.0 to 655.3 (A) (*3)
0.01 to 99.99, 100.0 to 655.3 (A) (*3)
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.001 to 9.999, 10.00 to 65.53 (Ω) (*1)
0.01 to 99.99, 100.0 to 655.3 (mH) (*2)
0.01 to 99.99, 100.0 to 655.3 (mH) (*2)
0.01 to 99.99, 100.0 to 655.3 (A) (*3)
0.01 to 99.99, 100.0 to 655.3 (A) (*3)
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.01 to 10.00
0.01 to 10.00
0.0 to 100.0
0.0 to 100.0
0. to 50. (%)
0. to 50. (%)
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.00 to 10.00
0. to 9999. (ms)
×
[◯= Allowed
= Not permitted]
Default Setting
Setting
SJ700
during operation
L700
(allowed or not)
-FE(CE) -FU(UL)
-F(JP)
×
00
00
00
00
×
00
00
00
00
00
×
00
00
00
00
00
00
×
00
00
00
00
00
×
×
00
00
00
00
×
00
00
00
00
×
00
00
00
00
00
00
00
×
00
00
00
00
×
00
×
00
00
00
00
×
00
00
00
00
×
00
00
00
00
1
1
1
×
1
1
1
1
×
1
1
1
1
1
×
×
1
1
1
1
×
1
1
1
1
1
1
×
1
1
1
1
1
×
1
1
1
1
1
×
×
1
1
1
1
×
0
0
0
0
×
[◯= Allowed
= Not permitted]
Default Setting
Setting
SJ700
during operation
L700
(allowed or not)
-FE(CE) -FU(UL)
-F(JP)
00
00
00
00
×
00
00
00
00
×
00
×
00
00
00
×
Factory set
×
4
4
4
4
×
4
×
4
4
4
1,590
1,590
1,590
1,590
1,590
1,590
1,590
1,590
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
100.
×
×
×
×
×
×
×
×
×
×
Depending on
×
motor capacity
×
×
×
×
×
×
×
×
×
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
×
100.
100.
100.
100.
100.
100.
×
50.
50.
50.
×
×
50.
50.
50.
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
1.00
1.00
1.00
1.00
100.
100.
100.
100.
Change
during operation
(allowed or not)
Change
during operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

L700 series

Table of Contents