LG BLGRESU10HP Installation Manual

Residential battery unit
Hide thumbs Also See for BLGRESU10HP:

Advertisement

Quick Links

/04/2021
INSTALLATION MANUAL
Residential
Battery unit
LG Electronics strongly advises users to exercise due care in following LGE's
product installation manual. A warranty claims are invalid if damage is caused
by human error, inconsistent with the installation manual.
MODEL
LG ESS HBP 10H
(BLGRESU10HP)

Advertisement

Table of Contents
loading

Summary of Contents for LG BLGRESU10HP

  • Page 1 /04/2021 INSTALLATION MANUAL Residential Battery unit LG Electronics strongly advises users to exercise due care in following LGE’s product installation manual. A warranty claims are invalid if damage is caused by human error, inconsistent with the installation manual. MODEL LG ESS HBP 10H...
  • Page 2: Table Of Contents

    The information included in this manual is accurate at the time of publication. However, this manual is subject to change without prior notice. In addition, the illustrations instructions. Please note the images shown are for illustration purposes only. Contents 1 Safety 3.2 Installation process for Remote Monitoring Device (RMD) 3.2.1 Prepare for installation using RMD 1.1 Symbols...
  • Page 3: Safety

    Do not dispose of the product with household waste The Product includes internal fault mechanisms designed to prevent failures and subsequent risk hazards. However, LG Electronics cannot guarantee safety performance of the Product is ever exposed to abuse, damage or negligence.
  • Page 4: Warning Label

    : Electrical license for battery installation required by the country or state Battery CE / RCM / IEC 62619 / UL1973 / Pack IEC62477-1 Repair the battery by disassembly is possible only at the LG Service Center or by Emissions Class 9 Transportation UN38.3...
  • Page 5: Features

    2.3 Maintenance 1. Short Circuit Current/Duration Short Circuit Current 1.106 kA BLG RESU10HP does not require maintenance during normal operation if properly installed Duration 0.97 ms per the installation manual. In the event of fault, contact the regional service center. 2.
  • Page 6: Basic Lifting Guide

    3.1.2 Basic lifting guide 5. Pull out Battery Module B. Refer to below guide for lifting and carrying the Battery Control Unit and Battery Modules during installation. Handling position 6. Pull out Battery Module A. Installer A Installer B 7. (Optional) Pull out the parts for wall mounting.
  • Page 7: Clearance

    3.1.5 Clearance 3.1.8 System Clearance the proper ventilation and installer convenience. pack and inverter should be in accordance with the installation guide manual of the inverter. Ceiling NOTE 500 mm An external DC isolator may be installed within the clearance zone. Minimum clearances Ceiling (20") may be greater according to local regulations.
  • Page 8 7. Remove bubble wrap from Battery Control Unit Standing bracket 1 on the wall. connectors of Battery Control Unit and the warning label of Battery Modules. Standing bracket 1 4. Place Battery Module B on the rear Battery Module B side of Module Connect plate.
  • Page 9 10. Connect the power and sensor 14. Realign the Battery Control Unit. connectors on the right and left sides (2 each). Assemble the connectors until you hear a “Click”. After that, lock the power connector by pressing TPA (Terminal Position Assurance). Sensing connector Power connector “Click!”...
  • Page 10: Installation Process For Remote Monitoring Device (Rmd)

    19. Re-attach the top cover. 23. Assemble the adapter or cap according to regional regulations. * Tighten the M5xL65 Flange Bolt Then insert the power and (4ea) with a torque of 5N·m. communication cables through the holes from outside of the pack. * Arrange the internal cable as required to avoid blocking the holes for external cables.
  • Page 11 LGES recommends the use of at least 8 fasteners for Wall Mounting Bracket Bottom and 2 fasteners for Wall Mounting Bracket Top. Label * Check “LG HBP 10H Wall Mounting (Optional)” on the Wall middle side of Drill Template Battery Module B Rear before drilling.
  • Page 12 9. Place the Battery Control Unit on 13. Remove one spacer by lifting one Battery Control Unit top of the spacers, and align with the side of the Battery Control Unit. After Battery Module. Lift (just few mm) that, remove the other spacer in the same way.
  • Page 13 17. Plate the Wall Mounting Bracket Top 21. Assemble the adapter or cap Support in right plate as shown in according to regional regulations. Insert the RMD ethernet cable using three (3) M6 Flange Bolts through Hole #2 and connect the cable.
  • Page 14: Prepare For Installation Using Rmd

    25. Re-attach the Front Protection Cover (RMD) with M5 PH bolt 6ea. Remote monitoring device (RMD) is a remote device that can install and monitor a battery pack through App. and web. 3.2.1 Prepare for installation using RMD Front Protection Cover 3.2.1.1 Installer Sign In 3.2.1.1.1 Visit https://resumonitor.lgensol.com 1.
  • Page 15 3.2.1.3 User Registration 9. Select the “Owner” option. 10. Enter your ID and Password. 3.2.1.3.1 Visit https://resumonitor.lgensol.com 11. Click the “Sign In” button. App. 3.2.1.3.2 Create an Owner account. 1. Select the “Owner” option. 2. Select “Create Account”. NOTE 3. Review the General Data Protection Regulation (Privacy Policy) and check “I Agree”...
  • Page 16 3.2.2.3 User Agreement 3.2.2.5 QR Code Scan The QR code scanning method is as follows. 1. Search the product which you will install. 2. Get the agreement of privacy policy for the customer. 3. If the customer agrees the privacy policy, have customer’s personal information. Select Prime: Fixed at 2 FLEX: Select from 2 to 4...
  • Page 17 3.2.2.6.2 Wi-Fi Connection If you are using an ethernet connection and do not wish to use Wi-Fi, simply click the “Next” button. IoT Hub Connection String: Enter the unique string provided to you in order to access the Azure IoT Hub (cloud server). Scan AP( ): Wi-Fi-network currently available for connection is displayed in The string format is as follows: SSID( ): Enter the name of the Wi-Fi-network to connect(You can enter it manually without...
  • Page 18: Cable Connections

    3.3 Cable Connections 4. Section E: Battery power port a) Connect the ground wire to Terminal 2. b) Connect the negative line of the power cable to Terminal 3. c) Connect the positive line of the power cable to Terminal 1. Blocks when choosing the battery power cable and cable sheath for peeling.
  • Page 19: Commissioning

    CAUTION 2. Ready : Battery is ready for operating normally. If the battery pack or the inverter indicates FAULT or fails to operate, contact LG Electronics regional contact point or your distributor immediately. 3. Charge : Battery pack is charging.
  • Page 20: Troubleshooting Guidelines

    1. Check if the inverter recognizes the battery. Refer to the inverter’s troubleshooting guide for battery setup instructions. company. 2-1. Send the fault ID to LG Electronics regional contact point. 6. Loosen 4 bolts and remove the Top 2-3. Wait further instruction from LG Electronics.
  • Page 21 Standing type: 12. Disconnect the power and sensor connectors on the right and left sides 7-a. Loosen six (6) M6 bolts and disassemble (2 each). This step should undergo a deliberate visual inspection by the installer before proceeding. Standing Bracket #1 from the wall. 1) Power connector: Pull the TPA press the button at the...
  • Page 22: Contact Information

    If the battery pack seems to be damaged, contact LG Electronics regional contact point or your distributor. Use the contacts below for technical assistance. These phone numbers are available only during business hours on weekdays.
  • Page 23: Appendix

    7. Appendix 7.2 RMD Applications 7.1 Connection in BLG RESU10HP parallel battery system How to check the battery status is as follows. CAUTION Parallel battery system can only be applied between products of the same energy. First, proceed with RMD Wi-Fi direct connection as shown below. 7.1.1 Setting for communication termination resistor (About Section Section C...
  • Page 24 Fault Name error code Support action required Return the battery to LG Over Voltage Fault2 DiagResultFault2 0x0001 Electronics. Under Voltage Fault2 DiagResultFault2 0x0002 Battery pack On and check additional errors. In case of normal operation, Charge the First, proceed with RMD Wi-Fi direct connection as shown below.
  • Page 25 3) BMS, DC/DC and RMD Update Can upgrade F/W. Upgrade is performed on the following three targets. 7.2.3.1 User Agreement - RMD Visit https://resumonitor.lgensol.com and Sign in. - BMS - DC/DC 3. According to the target you want to update, click the 'Choose File' button. correctly, click the 'Send' button.
  • Page 26 7.2.3.2 Battery Installation (RMD Setup) 123456 and can be changed in the Web UI. 1. Server Use: Decide whether to use (connect) to the cloud server. Search and access the SSID of the RMD AP from a device (hereinafter referred to as a device) supporting WLAN Station functions such as a smartphone.
  • Page 27 1. Click the Scan AP button on the top right of the Web UI. 2. The number of APs available is displayed in a pop-up window. 3. Select the AP to access from the SSID combo box, enter the password and click the Connect button(Manual input is possible).

This manual is also suitable for:

Ess hbp 10h

Table of Contents