Warning Label; Product Introduction; Technical Data; Dimensions And Weight - LG BLGRESU10HP Installation Manual

Residential battery unit
Hide thumbs Also See for BLGRESU10HP:
Table of Contents

Advertisement

1.3

Warning Label

Product/warning label and Battery Control Unit's traceability label are behind the front cover.
The front cover opens by turning the front cover handle counterclockwise. Battery Modules'
traceability labels are attached to the side of the Battery Modules.
Handle
Turn counterclockwise
1. Product/Warning Label
2. Traceability label
2-1. Battery Control Unit
2-2. Battery Module
the following skills and experience:
(backup) systems
Knowledge of the dangers and risks associated with installing and using electrical
devices and acceptable mitigation methods
Knowledge of the installation of electrical devices
Knowledge of and adherence to this guide and all safety precautions and best
practices
: Knowledge of local installation standards
: Electrical license for battery installation required by the country or state
Repair the battery by disassembly is possible only at the LG Service Center or by
1
2-1
2-2
2-2

2 Product Introduction

2.1 Technical Data

2.1.1

Dimensions and Weight

BLG RESU10HP
Part Number
TLB00983101
Width
504 mm (19.8")
Height
817 mm (32.2")
Depth
295 mm (11.6")
Weight
111 kg (244 lbs)
1)
1) Battery pack weights may vary slightly.
2.1.2

Performance

Electrical Characteristics
Usable Energy
1)
9.6 kWh
Battery Capacity
64.1 Ah
Voltage Range
350 to 450 VDC
Absolute Max. Voltage
595 VDC
Max. Current (charging/discharging) 14.3A @ 350V
Max. Power (charging/discharging)
5 kW
Peak Power
2)
(only discharging)
7 kW for 10 sec.
Peak Current (only discharging)
20.9 A for 10 sec.
Communication Interface
RS485/ CAN
DC Disconnect
Circuit Breaker
Connection Method
Spring Type Connector
User Interface
LEDs for Normal and Fault Operation
Operating Conditions
Installation Location
Indoor/Outdoor
Operating Temperature
charge
discharge
Operating Temperature
59°F to 86°F (15°C to 30°C)
(Recommended)
Storage Temperature
-22°F to 140°F (-30°C to 60°C), acceptable for 7
days in total
-4°F to 113°F (-20°C to 45°C), acceptable for the
-4°F to 86°F (-20°C to 30°C), acceptable for months
7~12
Humidity
5% to 95%
Altitude
Max. 6,562 ft (2,000 m)
Cooling Strategy
Natural Convection
Safety
Cell
Battery
Pack
Emissions
Transportation
Ingress Rating
1) Value for battery pack only. Maximal usable energy at the AC output may vary by condition,
2) Peak current excludes repeated short duration (less than 10 sec. of current pattern).
817 mm
(32.2")
504 mm
295 mm
(19.8")
(11.6")
14°F to 122°F (-10°C to 50°C)
-4°F to 122°F (-20°C to 50°C)
UL1642
CE / RCM / IEC 62619 / UL1973 /
IEC62477-1
FCC
Class 9
UN38.3
IP55
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ess hbp 10h

Table of Contents