Mitsubishi Electric LE-50PAU Instruction Manual page 24

Power amplifier/tension controller
Table of Contents

Advertisement

3. Stop gain / stop bias
MODE
Special display
Current stop gain value
Current stop bias value
The muneric value displayed is incremented / decremented each time when the [INC ] key or [DEC ]
key is pressed during numeric value increment / decrement operation. When these keys are kept
pressed, the numeric value is incremented / decremented at high speed automatically.
When it is not necessary to change the numeric value, press the [SET] key as it is, by which the follow-
ing setting is executable. The step is resumed to the last setp each time when the [MODE] key is
pressed.
4. Timer setting
MODE
Special display
Current stop timer value
Current aux. power
source timer value
The numeric value displayed is incremented / denremented each time when the [INC ] key or [DEC ]
key is pressed during numeric value increment / decrement operation. When these keys are kept
pressed, the numeric value is incremented / decremented at high speed automatically.
When it is not necessary to change the numeric value, press the [SET] key as it is, by which the follow-
ing setting is executable. The step is resumed to the last setp each time when the [MODE] key is
pressed.
When the [INC ] key is pressed with the [MODE] key
pressed, the gain / bias setting mode is turn on.
INC
When the same oeration is performed again , the
mode is reset and the special display mode is
resumed. (Wait for aprox. 1 second after pressing the
[MODE] key, and press the [INC ] key.)
INC
DEC
Setting is executable
Numeric value
to 0 to 300%
increment / decrement
INC
DEC
Numeric value
Setting is executable to 0.0
increment / decrement
to 9.9, 10 or 60% (2 digits).
When the [DEC ] key is pressed with the [MODE]
key pressed, the stop timer / aux. power output timer
setting mode is turn on.
DEC
When the same oeration is performed again , the
mode is reset and the special display mode is
resumed. (Wait for aprox. 1 second after pressing the
[MODE] key, and press the [DEC ] key.)
INC
DEC
Numeric value
Setting is executable to 0 to
increment / decrement
9.9sec., or 10 to 30sec. (2 digits).
INC
DEC
Numeric value
Setting is executable to 0 to
increment / decrement
9.9sec., or 10 to 30sec. (2 digits).
20
MODE
Correction
SET
MODE
Correction
SET
MODE
MODE
Correction
SET
MODE
Correction
SET
MODE
INC
DEC