Advertisement

4. Practical operation

4.1 Setting of winding diameter / taper ratio
The practical operation procedure for operator is as shown below;
Connection of cable
Turning on amplifire power source
Display of version
for several sec.
At the first time
M I N
最小
T S N
S M L
T S N
L R G
T S N
M A X
最小
T S N
設定
クリア
(Example of setting at D1=150mm)
M I N
T S N
セ ッ テ イ
クリア
S E T T N G
< Appendix >
When performing the constant tension operation, the operation is executable simly by setting the min-
imum diameter (D1) and maximum diameter (D4).
When D1 or D4 is "0" ( initial value ), no power amplifire output is sent out.
When D1 is equal to or greater than D4 (D4 is not equal to 0 ) after setting both values to range of 1 ~
1,999, the setting error message is displayed.
In such a case, reset the message by pressing the [ クリア ] key, and corredt D1 or D4.
D1 ~ D4 can be set to range of 1 ~ 1,999, and T1 ~ T4 to that of 20 ~ 500.
If they are set to out of designated range, the setting error message is displayed when the [ 実行 ] key
is pressed. In such a case, no setting is acceptable.
(D2, T2) and (D3, T3) may be used directly at initial value (0, 0).
When T2 is "0" even if D2 is set, such setting is ignored. The same applies to D3 and T3 (See page 17.)
When setting, be sure to secure the following relationship.
D1<D2<D3<D4
Note that only T1 (=100%) is acceptable to winding, and T4 (=100%) to unwinding.
For other than D1<D2<D3<D4 (excluding D2, D3=0), the error is displayed when it is detected during
error check.
Such data is written in EEPROM memory built in LE-50PAU each time when the [ 実行 ] key is pressed.
Screen displayed
prior to power off
D 1 = * * * *
T 1 =
1 0 0
D 2 = * * * *
T 2 =
* * *
D 3 = * * * *
T 3 =
* * *
D 4 = * * * *
T 4 =
1 0 0
When the [INC ] key or [DEC ] key is pressed, "
screen is moved. In this case, it becomes possible to set the numeric at the
line displayed by "
unwinding, and T1 (=100%) for winding.
When the [ 設定 ] key is pressed, the numeric setting mode is validated here-
after. When [ クリア ] key or [ 実行 ] key is pressed, the setting mode is reset.
実行
Correction
D 1 =
1 5 0
T 1 =
1 0 0
エ ラ -
E R R O R
When the power source to the LE-50PAU is
turned of after connecting the cable between
LE-5AP and LE-50PAU, the initial screen is
displayed in a meanwhile.
m m φ
When the [ 最小 ] key or [ 最大 ] key is pressed,
m m φ
the screen as shown at left is displayed.
m m φ
The screen is changed over every 2 lines.
m m φ
" mark. Note that only T4 (=100%) is acceptable for
Error
The left drawing shows an example for case
when D1 is set to 150mmφ with "
placed at MIN line. When the setting is executed
erroneously, press the [クリア] key and start the
Valid
operation from [ 設定 ] key.
m m φ
If [0] key is pressed, it is possible to change to
correct value directly.
[ 最小 ] key or [ 最大 ] key is acceptable in any
screen. The operation remains invalid until [ 実
行 ] key is pressed within the screen being
changed.
31
" mark within the
" mark

Advertisement

Table of Contents
loading

This manual is also suitable for:

Le-50pau-set

Table of Contents