3. Turn on the power switch in the cabinet.
The recommended current specification for the external power circuit breaker connected to
the server is as follows:
AC power supply: 32 A
DC power supply: 63 A
4. Power on the server.
The power-on methods of the server vary according to the following scenarios:
The power supply units (PSUs) are properly installed but not powered on.
Connect the external power supply to the PSUs. Then the server will power on with the
PSUs.
The default value of System State Upon Power Supply is Power On, which indicates
that the server automatically powers on after power is supplied to the PSUs. You can
change the value of System State Upon Power Supply on the iBMC WebUI.
The PSUs are installed properly and powered on. The server is in the standby state (the
power button/indicator is steady yellow).
− Press the power button/indicator
to power on the server.
− Power on the server using the iBMC CLI.
Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter y or
Y to power on the server.
− Power on the server using the iBMC WebUI.
Choose System > Power > Power Control, click the Power On button, and click Yes in
the dialog box displayed.
− Power on the server using the remote virtual console.
Log in to the remote virtual console. On the KVM screen, click
toolbar, select Power On, and click OK to power on the server.
5. Check the status of the indicators.
If the power indicator
is steady green, the PSUs are powered on.
4
If the power button/indicator
5 Appendix: Hazardous Substance Statement for
Electronic and Electrical Products
Part
Cd
PCBA
Cables
Accessories
Equipment
Batteries*
This statement for electronic and electrical products complies with SJ/T 11364.
◯: all homogenous part materials under GB/T 26572 hazardous substance limit
x: at least one homogenous material exceeds GB/T 26572 hazardous substance limit
*: when in use by the product
or
on the
is steady green, the server is powered on.
Hazardous Substances
Pb
Hg
Cr (VI)
PBBs
PBDEs
×
×
×
×
×
5