Table 5 Sound Level Of The Drive Shelf; Table 6 Efficiency And Power Factor Of The Power Supply Unit - Fujitsu ETERNUS AB Series Site Planning Manual

Hide thumbs Also See for ETERNUS AB Series:
Table of Contents

Advertisement

1.
ETERNUS AB/HB Installation
Installation Specifications
Environmental
conditions
Noise
emission (*7)
*1:
A 2U power distribution unit is composed of two 1U power distribution units.
*2:
These values are for each shelf when 24 drives are installed.
*3:
The value in the parentheses for the controller shelf and drive shelves includes the mass of the rack rail kit.
*4:
These values are for the maximum load when all the available options are installed in an ETERNUS AB/HB.
*5:
The operating test was performed in environments compatible with the Operating Condition Class A3 of
the EU eco-design directive (ErP Directive 2009/125/EC).
*6:
The operating test was performed in environments compatible with the Operating Condition Class A2 of
the EU eco-design directive (ErP Directive 2009/125/EC).
*7:
For details about the sound level of the drive shelf, refer to
12).
Table 5
Sound Level of the Drive Shelf
Sound pressure level
Sound power level
Table 6
Efficiency and Power Factor of the Power Supply Unit
Component name
Shelf
ETERNUS AB5100
ETERNUS AB6100
ETERNUS AB6100
DE224C drive shelf
*1:
Indicates the rated load against the rated output of the PSU.
Item
Temperature
Operating
Not operating
During shipment
Temperature gradient
Humidity
Operating
Not operating
During shipment
Humidity gradient
Maximum wet bulb temperature
Altitude above sea level
Airborne dust
Gas concentration tolerance level
Oil vapor
Seawater (salt corrosion)
Sound pressure level
Sound power level
DE212C
64 dBA
6.4 B
80PLUS®
20 % (*1)
Platinum
91.8 %
93.5 %
Titanium
94.7 %
Platinum
91.8 %
ETERNUS AB5100
5 – 40 °C (*5)
-40 – 70 °C
-40 – 70 °C
15 °C/Hr or less
8 – 85 %RH (*5)
5 – 95 %RH
10 – 95 %RH
30 %/day or less
29 °C
0 – 3,048 m
0.15 mg/m
Cl
: 6.8 ppb or less, H
2
SO
: 37 ppb or less, NH
2
NO
: 52.3 ppb or less, O
2
HCl: 6.6 ppb or less, HF: 3.6 ppb or less
3
0.2mg/m
If the ETERNUS AB/HB is installed on the
ocean or premises within 0.5 km from the
coast, necessary measures must be taken
to prevent salt corrosion.
72 dBA
7.2 B
"Table 5 Sound Level of the Drive Shelf" (page
DE224C
51 dBA
72 dBA
6.7 B
7.2 B
Efficiency
50 % (*1)
100 % (*1)
94.2 %
92.7 %
94.2 %
91.4 %
96.1 %
94.5 %
94.2 %
92.7 %
12
ETERNUS AB6100
10 – 35 °C (*6)
8 – 85 %RH (*6)
3
or less
S: 7.1 ppb or less,
2
: 423.5 ppb or less,
3
: 5 ppb or less,
3
or less
69.1 dBA
7.2 B
DE460C
Power factor
Output
50 % (*1)
0.980
Multiple output
1.000
Single output
1.000
Single output
0.980
Multiple output
Site Planning Guide

Advertisement

Table of Contents
loading

Table of Contents