Installation Methods; Figure 16 Floor Dimensions Of The Rack (Of 19-Inch Racks) - Fujitsu ETERNUS AB Series Site Planning Manual

Hide thumbs Also See for ETERNUS AB Series:
Table of Contents

Advertisement

1.
ETERNUS AB/HB Installation
Installation Environment

Installation Methods

Perform one of the following rack installation methods to ensure the safe use of an ETERNUS AB/
HB that is installed in a rack:
-
To secure a rack, use a rack without stabilizers and secure it to the building with the leveling
feet.
-
If a rack is not to be secured, make sure to use a rack with stabilizers and use these stabilizers
to prevent the rack from toppling over.
The installation method that should be used depends on the installation location, the floor
conditions, and the type of racks where the ETERNUS AB/HB is to be installed. Contact your
installation contractor for more details regarding installation and how the installation should
actually be performed.
An installation diagram when installing a rack (or the floor dimensions of the rack) is shown below.

Figure 16 Floor Dimensions of the Rack (of 19-inch Racks)

Front
47 mm
919 mm (leveling feet)
140 mm
733 mm (caster)
826 mm
1,013 mm
1,050 mm
Caster
Leveling feet
Cable slot
95 mm
37
Rear
Site Planning Guide