HP 82479A Owner's Manual page 55

Data acquisition pac
Table of Contents

Advertisement

Keywords
3.4 INTERRUPT SUBPROGRAMS
Three BASIC subprograms provided in the LITIL. ITY file may be used for convenient interrupt
programming. They are:
MONLOW
CHLL MOHLOW YC channel numbers errorcode
The parameters are as follows:
channel number - an HP 3421A channel number (range = 00 - 29).
errorcode — Returns 0 if there were no errors, or the number of the error generated.
This subprogram sets up the HP 3421A to source a service request (SRQ) when the specified input channel
goes low and waits for the SRQ.
MONHIGH
CHLL MOMHIGHC channel numbers errorcode
The parameters are as follows:
channel number - an HP 3421A channel number (range = 00 - 29).
errorcode - Returns O if there were no errors, or the number of the error generated.
This subprogram sets up the HP 3421A to source a service request (SRQ) when the specified input channel
goes high and waits for the SRQ.