6002 Output - HP 211B Operating And Service Manual

Square wave generator
Table of Contents

Advertisement

Section
V
Paragraph 5-13
to 5-17
GR874 -W50
410221A
50Q
TEE
2118
TRIG. SOQ
Figure 5-3.
50 Output Pulse Check
5-13.
502 OUTPUT
5-14.
Pulse Amplitude
a. Refer to Figure 5-3 and connect required equip-
ment.
b. Set Model 211B controls as follows:
MULTIPLIER............... 1M
FREQUENCY DIAL......... 1
SYMMETRY..........0c
cee 50% duty cycle
AMPLITUDE
(v across 502). .5
VERNIER........cceseeeceee CCW
TRIGGER
POLARITY........
negative
c. Set Sampling Oscilloscope controls
and plug-in
as follows:
TIME SCALE........-000006 200ns/cm
VERNIER,....
ccc ececceees
CAL
TIME
SCALE
MAGNIFIER...
X1
TRIGGERING. ........002 eee normal
TRIGGER
SLOPE...........
negative
MODE
AND STABILITY...... for stable trace
CHANNEL
SELECTOR....... channel A
SENSITIVITY.
.........0..00-
50mV/cm
VERNIER..........eeceee
CAL
RESPONSE........eccceceee
normal
d. The oscilloscope display should be no more
than 4 cm
(2 V)in amplitude.
]}f 4 cm or less is
observed the ratio between CW and CCW
is at least
2.5 to
1. Therefore at a 0.05 V pulse amplitude
setting the minimum
of 0.025 V output
can be
obtained.
5-15.
Pulse shape
a. Set Oscilloscope TIME SCALE to 20ns/cm.
b. Set Model 211B FREQUENCY dial to 5, set
AMPLITUDE
(V across 502) switch to 5 and adjust
VERNIER for a pulse amplitude of 5 V (10cm).
c. Change the time scale MAGNIFIER to X20.
Move the leading edge of the pulse to the center of the
graticule,
5-4
Model
211B
f. The following leading edge characteristics
should be observed.
Rise Time 10% to 90%. . . No more than 5 cm (5ns)
Preshoot..............
No more than 5 mm (5%)
Overshoot and Ringing. . No more than 5 mm peak
(5%)
g. Adjust Oscilloscope DELAY control for display
of pulse trailing edge.
h. The following trailing edge characteristics
should be observed
Fall Time 10% to 90%...Nomore than 5 ¢m (5ns)
Preshoot..............
No more than 5 mm (5%)
Overshoot and Ringing..
No more than 5mm peak
;
(5%)
5-16.
6002 OUTPUT
5-17.
Pulse Amplitude
a. Refer to Figure 5-4 and connect required equip-
ment.
b. Set Model 211B controls as follows:
MULTIPLIER..........-+445 10K
FREQUENCY
DIAL.......... 10
SYMMETRY.............26-
50% duty cycle
AMPLITUDE
- 6002......... CW
c. Set High Frequency Oscilloscope and plug-in' s
as follows:
SWEEP TIME.............4- 2us/em
VERNIER........0cceeeee CAL
HORIZONTAL DISPLAY...... X1
VERNIER.......0000ceeees CAL
TRIGGER
SOURCE..........
internal
TRIGGER SLOPE...........
negative
CHANNEL
SELECTOR....... channel A
SENSITIVITY. ...........006. 1 V/em - de
VERNIER.........2000000. CAL
POLARITY.............000- positive
SWEEP SELECTOR.........
main
10003 B
Figure 5-4.
6002 Output Pulse Check