BUS address  Function 
20H:D3-D1  Set line of VBI data  
slice 
20H:D0 
16LSB limit 
21H:D7-D5  Start phase of V at 
THR-V 
21H:D4-D3  Delay adjustment of 
HD-OUT 
21H:D1 
BSRY filter 
21H:D0 
BSRC filter 
22H:D7 
HD-OUT of polarity 
22H:D6 
VD-OUT of polarity 
22H:D5 
Polatity of Field  
22H:D4 
H/V-OUT through 
22H:D3 
Polarity of CKOUT 
22H:D2 
V.BLK processing 
22H:D1 
Y output Amplitude 
23H:D6 
Cb/Cr phase 
23H:D5-D4  50/60Hz VD cotrol 
23H:D3 
Field Det on non-signal  The detection of Field is set up on non-signals. 
23H:D2-D0  Ext VD phase 
24H:D7-D5  Horizontal phase for 
field detection 
24H:D4 
V count 
24H:D3 
V count reset 
Feb./2005 
Contents 
The line of VBI-data-slice is set up. 
Usually used with center. 
When it uses at the outside synchronism, it uses for the 
adjustment,  when  the  phase  of  the  outside  VD-pulse  and  the  input 
signal are shifted. VBI and Macrovision detection line move at 
the same time, too. 
It limit less than 16LSB at the Digital output. 
Use by ON, when you use with 601/656 output. 
The phase of VD is set up.  
Bus:111 can't be set up.  
When Thru of V, Set the delay of HD-Pulse.The variability is
32W〜44W (1W=27MHz).  
It usually uses on ON. 
It usually uses on ON. 
The polarity of the HD output is chosen.  
The polarity of the VD output is chosen.  
The polarity of the Field output is chosen. 
H/V-OUT in 601 output is chosen.  
656:H/V-pulse equal to 656.  
Through:H/V-pulse equal to the input signal. 
The polarity of the CKOUT is chosen. 
Processing of V-Blanking is chosen. 
It usually uses on O:NORMAL. 
The period of blanking in NORMAL are Y=16LSB (8bit) and 
C=128LSB (8bit). Through is for the test. 
The amplitude of the Digital output is changed. 
It usually uses on O:1.71875. "1" is for the test. 
The output of Cb and Cr can change.  
0:Digital Format Normal 
1:change 
VD output is controlled. (It becomes effective when it is set
up in 601 output.) 
00:Free run 
01:It is fixed on 50 or 60 on non-signal. 
    Frequency to fix depends on TVM2. 
10:When  Video-system  is  MANUAL  control,  a  setup  is  always  fixed
on TVM2. 
11:It is always fixed on TVM2 at MANUAL.  
It is fixed on TVM2 at non-signals.  
It is A phase in the external-VD-input. 
Variable is -7.94[μs]  〜  5.96[μs]. 
It is H-phase of Field-detection. 
It is the phase margin. Use with Bus:100. 
 
It is the allowable range of V-counter.  
It can set margin of "V-Sep phase and H-counter".  
It usually uses on 0. 
It is the specifications of reset of V-counter.  
When ON, It can reduce field-miss-detection. 
It usually uses on ON. 
 
TC90101FG  
 