5.  H/V Sync processing
TC90101FG has H/V sync separation circuit and regenrates HD/VD pulse.
The phase and width of HD/VD pulse are controled via THRHV at sub address 22hex.
[0] : 656 format.
[1] : Syncronized with input signal.
 
6. D2 signal (525p/525p component) processing
TC90101FG has D1 and D2 detection circuit and Sync processing for D2 signal.
D2 signal is converted as 4:2:2 digital signal by internal ADC. (Sampling rate of Y ADC is 27MHz.)
ID-1 data slice for 525p is available but It's not available to use picture implrovement function and
Noise level detection, (The sliced data of ID-1 can be read via IIC.)
 
7. T.O.F (Take Off filter)
TC90101FG has Take Off filiter which is in front of color decoder.
Characteristic of T.O.F is set via TOF at sub address 0C hex.
[000] : Off
[001] : type 1- [111] : type 7
(Type 1 : BPF.)
8. Y process
a) Vertical enhancement : adjustable coring, gain, and non-linear performance
b) LTI function
The performance of this function is controlled via Iregisters at 04 and 05 hex.
f0 : 3.3MHz / 2.2MHz
Coring : 0.8IRE/1.6IRE/3.2IRE/6.4IRE
Gain : Off / 1/8 / 1/4 / 1/2
c) Sharpness
The performance of this function is controlled via Iregisters at 02 and 03 hex.
f0 : 4.2MHz / 3.3MHz
Coring : 0.8IRE/1.6IRE/3.2IRE/6.4IRE
Gain : -1/4 - Off - 1/2
d) Noise canceller
The performance of this function is controlled via Iregisters at 04 hex.
f0 : 4.2MHz / 3.3MHz ( It uses same register with f0 of sharpness control.)
Coring : 0.8IRE/1.6IRE/3.2IRE/6.4IRE
Gain : -1/4 - Off - 1/2
e) Contrast
Control range : ×(1/2) - ×2.4
f) Brightness
it's effective at the periode of picture signal portion.
Control range : -128LSB - 128LSB ( 10bit unit)
 
9. C process
a) ACC control : A reference level is set up by register ACC LEVEL.
b) Killer control : sensitivity of killer is set via [BUS KILLV] at sub address 37 hex.
In case Killer detection, comb filter for Y becomes off.
c) HUE control : Hue control is available for CVBS and C signal of NTSC system.
Hue bias : 0 --- +45degree
Hue range : -45 degree --- +43.6degree
d) Sub color gain control
Amplitude of Cb and Cr signals are controlled via IIC.
Control range is –6dB --- +2.8dB