To make controller settings:
1. Mouse-over the controller and click the Settings button.
2. Make setting changes as required.
 Enter, change or delete the alias in the Alias field
 Enable SMART Log – Check the box to enable or uncheck to
disable
 SMART Polling Interval – Enter a value into the field, 1 to 1440
minutes
 HDD Power Levels – Choose time periods from the dropdown
menus.
 Level 0: Disabled
 Level 1: Park the read/write heads
 Level 2: Lowers disk rotation speed
 Level 3: Spins down the disk (stops rotation)
 Coercion – Check the box to enable or uncheck to disable.
This feature is designed for fault-tolerant logical drives (RAID 1,
1E, 5, 10, 50, and 60). It is generally recommended to use
physical drives of the same size in your disk arrays. When this is
not possible, the system adjusts for the size differences by
reducing or coercing the capacity of the larger drives to match
the smaller ones.
 Coercion Method – Choose a method from the dropdown menu:
GB Truncate – Default. Reduce the useful capacity to the
nearest 1,000,000,000 byte boundary.