Table 8-1. DR4000 System Alert and Event Messages
Type/Number
Alert/Event Message
2012
Unable to detect filesystem type
on Data volume.
2013
Unable to detect filesystem type
on Namespace volume.
2014
Filesystem scan discovered
inconsistencies.
2015
Replication peer network
disconnected.
2016
NVRAM does not match the data
volume.
2017
Storage usage approaching system
capacity.
2018
Replication resync cannot
proceed.
2019
Out of space on replication target. Please clean up the filesystem.
2020
The filesystem has reached the
maximum allowable files and
directories limit. New file and
directory creation will be denied.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 1 / 1 0 / 1 2 - F O R P R O O F O N LY
88
Troubleshooting and Maintenance
Description/Meaning or Action
Contact Dell Support for
possible support assistance or
intervention.
Contact Dell Support for
possible support assistance or
intervention.
Please check the filesystem
report, and take the suggested
action.
Check access to remote site.
If this is a newly replaced
NVRAM, use maintenance
--hardware --reinit_nvram
commands to reinitialize the
NVRAM.
For more information, see the
Dell DR4000 System
Command Line Reference
Guide
.
Please clean up the filesystem.
Namespace limit has reached its
maximum.
Please clean up the filesystem.