Brother BAS-311E Service Manual page 97

Programmable electronic pattern sewer with cylinder bed e series
Hide thumbs Also See for BAS-311E:
Table of Contents

Advertisement

Turn the dial while pressing the STEP BACK switch to change the values.
Turn the dial while pressing the STEP BACK switch to change the values.
Possible setting
SW No.
memo-30
memo-31
memo-32
memo-33
memo-34
memo-35
memo-36
memo-37
memo-38
memo-39
Note:Ç · Î · Ï indicates that these functions are available for software versions MN-C · MND · MN-F or later.
Initial
Units
range
value
1 - 999
x 10ms
1 - 4
----
1 - 7
----
1 - 10
x 7.5
1 - 5
----
10 - 60
Xms
1 - 3
----
----
0 - 3
1 - 20
X0.1S
0 - 11
----
BAS-311E.311EL.326E.326EL
Chapter 6 Power supply and electrical parts adjustment
Time until feed mechanism starts moving after
10
work clamp has lifted.
1
Changes the feed speed. 1 (Fast)
Changes the possible sewing speed for a given stitch length.
1 (Fast)
7 (Slow)
1 (2,700/3 mm), 2 (2,600/3 mm), 3(2,500/3 mm),
3
4 (2,300/3 mm), 5 (2,000/3 mm), 6 (1,800/3 mm),
7 (1,200/3 mm)
Settings 1 and 2 are outside the warranty specification at the
time of shipment from the factory.)
Changes the feed timing
5
1 (Fast)
5 (standard)
Number of stitches sewn at 400 spm (10W speed) at sewing
0
start
Solenoid ON time changes when work clamp is being
lowered (solenoid specifications only)
40
10
(Quiet)
(High work clamp capacity)
Solenoid ON time to raise presser foot is changed.
(Standard) 1
1
1 (10 ms) 2 (20 ms) 3 (30 ms)
Gear ratio is automatically corrected when 2DD data is read.
0: Follows the model specified in DIP switch C.
1: Reads 2DD data as 311A data.
2: Reads 2DD data as 326A data.
3
3: Reads 2DD data as 341A/342A data.
[This function is available when panel PROM indication is
PL-C or later.]
Delay time from the point when the cassette is
1
clamped to the start of sewing when DIP switch A7 is
ON during automatic sewing
[Set value]
0: Sensor home position, 1: Center of sewing area, 2: Upper
left of sewing area, 3: Lower left of sewing area, 4: Upper
right of sewing area, 5: Lower right of sewing area, 6:
Sewing start point, 7: Sewing end point, 8: Upper left of
mask, 9: Lower left of mask, 10: Upper right of mask, 11:
Lower right of mask
[Procedure]
1. Select memory switch 39.
0
2. Change X and Y scales.
3. Step on start switch to return to home position, and
sewing data can be created with specified scales.
[Mask]
Upper left
of mask
Lower left
of mask
Explanation
4 (Slow)
10 (Slow)
60
3 (Upper limit)
¡
Mask is a rectangular frame
to cover the rounded edges
of sewing data.
¡
In the left figure, an oval is
sewing
data,
rectangle indicated with a
broken line is the mask.
ç
Î
and
the
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bas-326eBas-311elBas-326el

Table of Contents