Chapter 7
4. Choose Objects from the Tools Management menu.
5. Choose Logical Drive from the Objects menu.
6. From the Logical Drives menu, choose the logical drive you want to
prepare for expansion.
7. From the Logical Drive menu for the drive you want to prepare, choose
Properties.
8. Choose Virtual Sizing.
9. On the Virtual Size Feature menu, choose Enable, and confirm your
choice.
10. Press Esc twice to return to the Logical Drive menu.
If you need to enable virtual sizing on another logical drive, choose the
logical drive and repeat steps 6 through 10.
11. If there is more than one HP NetRAID-1M or 2M adapter installed
(including any integrated HP NetRAID controller), press Esc to return to
the Objects menu. Enable virtual sizing on the logical drives of all
adapters as necessary.
12. To exit, press Esc until you see the Exit? box, then choose Yes.
NOTE
Clearing a previous configuration does not reset the virtual
sizing setting for a logical drive. Use the Reset to Factory
Defaults option in Express Tools to disable virtual sizing for
all logical drives, or manually change the setting.
II. Create the NetWare Partition
1. Start NetWare 4.2.
2. Type NetWare load install.
3. Select Standard Disk Options.
4. Select Modify Disk Partitions and Hot fix.
5. The Available Devices are displayed. For an initial installation, only Free
Space will be displayed. Select Create NetWare disk partition to create
a NetWare partition on the logical drive (which has virtual sizing
enabled). The partition size will be 144 GB. Press Enter.