Errors (Level 2); Warnings (Level 3) - HP D5970A - NetServer - LCII Installation And User Manual

Hp netserver fcarray assistant - installation and user guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Appendix A
272 Power supply failure.
274 Power supply failure.
288 Over temperature. Temperature is above 70 degrees Celsius.
291 Over temperature.
517 Lost connection to server, or server is down.

Errors (Level 2)

9
Rebuild stopped with error.
10
Rebuild stopped with error. New device failed.
11
Rebuild stopped because logical drive failed.
18
Expand Capacity Stopped with error.
131 Consistency check on logical drive error.
132 Consistency check on logical drive failed.
135 A logical drive is critical.
141 Rebuild stopped with error.
142 Rebuild stopped with error. New device failed.
143 Rebuild stopped because logical drive failed.
147 Logical drive initialization failed.
152 Expand Capacity stopped with error.
385 Write back error.

Warnings (Level 3)

3
Hard drive error found.
4
Hard drive PFA condition found, this drive may fail soon.
22
Parity error found.
23
Soft error found.
24
Misc error found.
289 Temperature is above 50 degrees Celsius.
386 Internal log structures getting full, PLEASE SHUTDOWN AND RESET
THE SYSTEM IN THE NEAR FUTURE.