HP StorageWorks 6100 - Enterprise Virtual Array User Manual page 231

Hp storageworks mpx200 multifunction router user guide (5697-0306, january 2010)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

FcipRoute#%d: Synchroniz-
172238
ation Error on Receive
FcipRoute#%d: Decompres-
172239
sion Error on Receive
FcipRoute#%d: De-encapsu-
172240
lation Error on Receive
FcipRoute#%d: Transmit
172245
Failure
FcipRoute#%d: Remote Peer
172246
Disconnected
FcipRoute#%d: Failed to
172247
send FC Up/Down
FcipRoute#%d: FCIP Link
172249
Down
FcipRoute#%d: TCP Link
172250
Down
FcipRoute#%d: Remote Peer
172253
IP Address Validation
Failed
FcipRoute#%d: Tcp Cli-
172272
ent's connect attempt
failed
FcipRoute#%d: Tcp Serv-
172273
er's Listen attempt
failed
184515
FcipRoute#%d: TCP Link Up
FcipRoute#%d: FCIP Link
184536
Up
Indicates an error in the received FCIP PDU
FCIP
Error
Framing. The router will disconnect and recon-
nect with the remote router to clear the error.
Indicates that the receiver could not decom-
press a received FCIP frame. The router will
FCIP
Error
disconnect and reconnect with the remote
router to clear the error.
Invalid FCIP header received. The header is
invalid or improperly framed. The router will
FCIP
Error
disconnect and reconnect with the remote
router to clear the error.
FCIP PDU transmit request was rejected, typic-
ally caused by the TCP connection closing
when the send was submitted. Can also be
FCIP
Error
caused by lack of resources to accommodate
the send (should never happen). If this persists
and the TCP connection is up, a reboot is re-
quired to clear the condition.
The remote peer terminated the TCP connection
FCIP
Error
via a FIN or RST. The router will attempt to
restore the TCP connection.
Unable to notify the remote router that the
local FC link came up or went down. The TCP
FCIP
Error
connection will be closed and the router will
attempt to reconnect to the remote router.
The FC link went down. Check the FC cabling
FCIP
Error
and FC switch or drive statistics.
The TCP link went down. Check the Ethernet
FCIP
Error
cabling and Ethernet switch or peer device
statistics.
A TCP client attempted to connect to the router,
but the IP address did not match the address
FCIP
Error
of the remote router specified in the route
definition. Check the route definition, check
for network rogues fishing for open TCP ports.
Router was not able to open a TCP connection
with the remote router. Check the route defini-
FCIP
Error
tions on each router and check the Ethernet
cabling. Try to Ping the remote router.
TCP connection was closed before it was fully
FCIP
Error
opened. Router will restart its listen socket.
TCP connection was successfully established
FCIP
Info
with the remote router.
FCIP
Info
Local and Remote FC links are up.
MPX200 Multifunction Router
231

Advertisement

Table of Contents
loading

Table of Contents