Hp storageworks mpx200 multifunction router user guide (5697-0306, january 2010)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

iSCSI Port
hpstorageworks
Discovered iSCSI
CHAPsecret01
Initiator
iSCSI Presented
N/A
Target
NOTE:
These are examples of secret settings. Configure CHAP using settings that apply to your network
environment.
1.
Enable CHAP for the MPX200 discovered iSCSI initiator entry (CHAP can be enabled via CLI
only).
a.
If the iSCSI initiator is not listed when you execute the set chap command, do one of the
following:
• From HP Command View EVA, select Hosts, and then select the Add Host tab. Enter the
IQN name string.
• From the CLI, enter the initiator add command and add the iSCSI initiator that will
perform the discovery.
b.
If the iSCSI initiator is listed under the set chap command, then enable CHAP secret (for
example: CHAPsecret01).
• Select the index of the iSCSI initiator.
• To Enable CHAP, select 0, and then enter the CHAP secret.
2.
Enable CHAP for the MPX200 iSCSI port:
a.
To enable CHAP for the MPX200 iSCSI port using HP Command View:
• Select the appropriate iSCSI Controller, then select the IP Ports tab, and then select the
appropriate IP Port.
• Under Security, select Enabled in CHAP Status, and then enter the CHAP Secret (for ex-
ample, hpstorageworks).
• Select the Save Changes tab to save the changes.
b.
To enable CHAP for the MPX200 iSCSI port using the MPX200 CLI:
• Enter the set chap command.
• Select the appropriate Portal iqn name index that the initiator will log in to.
• Select 0 to enable CHAP.
• Enter a CHAP secret. For example: hpstorageworks.
96
MPX200 iSCSI configuration rules and guidelines
General Tab Secret
Add Target Portal
Log on to Target
hpstorageworks
CHAPsecret0