Fujitsu MAP3147 Scsi Logical Interface Specifications page 244

Scsi logical interface specifications 3.5 inch hard disk drives with internal scsi controller
Table of Contents

Advertisement

Sense Data Error Recovery Methods
C*
Q*
Name
45
00
Select/Reselect failure
47
00
SCSI parity error
48
00
INITIATOR DETECTED
ERROR message received
49
00
Invalid message error
4C
nn
Logical unit failed self-
configuration
4D
nn
Tagged overlapped
command
4E
00
Overlapped commands
attempted
55
04
Insufficient Registration
Resource
5C
01
Spindle synchronized
02
Spindle not synchronized. Rotational synchronization deviated.
5D
nn
SMART predictive failure SMART related sense data
90
00
Initiator's SCSI ID not
identified
C4
nn
Drive Failure
* C: Sense Code, Q: Sub-sense Code
5 - 10
Table 5.2
Sense and subsense codes (5 of 5)
A response wait time-out from the INIT was detected in the
RESELECTION phase.
A parity error was detected on the SCSI data bus.
The INITIATOR DETECTED ERROR message was received from
the INIT.
An unsupported or inappropriate message was received.
The IDD's initial setup failed. ('nn' is a Fujitsu unique code)
• A1: SA Read error (any 3/11/** error during SA read)
• A3: SA Read error (any 3/13/** error during SA read)
• A4: SA Read error (any 3/14/** error during SA read)
• A5: SA Read error (any 3/15/** error during SA read)
• A7: SA Read error (any 4/44/** error during SA read)
• A8: Invalid SA (Header/Check Sum)
• E0: Initial calibration failed
Before completing one command execution, new command having
the same tag number was issued to the same logical unit. (nn=queue
tag number)
1) Before execution of an untagged command was completed, the
same INIT issued a new command to the same LUN.
2) Before execution of a tagged command was completed, the same
INIT issued a command to the same LUN with the same tag. Or,
an untagged command was issued when not in the sense hold
state.
PERSISTENT RESERVATION OUT command is issued from
insufficient device server resource.
The rotational synchronization operation was completed.
12: The read error rate attribute has reached the failure threshold.
14: The frequency of grown defect allocation attribute has
reached the failure threshold.
43: The seek error rate attribute has reached the failure threshold.
56: The spin up time attribute has reached the failure threshold.
64: The remaining alternate sector count attribute has reached the
failure threshold.
FF: The drive is in test mode.
Since the SCSI ID of the INIT was not notified in the SELECTION
phase, the RESERVE, RESERVE EXTENDED, RELEASE AND
RELEASE EXTENDED commands cannot be executed.
A serious error was detected in the drive's control system. ('nn' is a
Fujitsu unique code)
00:
Abnormal Rotation of Spindle Motor
01:
Any error at Spindle Motor Start
30:
On track failure
Explanation
Sense
key
B
B
B
B
4
B
B
5
6
6
0, 1, 6
5
4