Dell PowerEdge M820 Owner's Manual page 102

Dell poweredge m820 systems owner's manual
Hide thumbs Also See for PowerEdge M820:
Table of Contents

Advertisement

Error Code Message Information
OSE0001
Message A runtime critical stop occurred.
Details
The system halted due to an exception while the operating system was running. This is a
kernel panic or bug check event.
Action
Review operating system logs and system video for additional information.
OSE0004
Message A soft shut-down initiated by platform event filter.
Details
A separate exception or status condition shutdown the operating system. (IPMI sensor type
20h - offset 04h).
Action
Review system event log for platform events capable of shutting the system down.
OSE0005
Message Agent is not responding.
Details
Graceful shutdown request to an agent via the BMC did not occur due to a system
hardware or software exception.
Action
Review operating system logs and system video for additional information.
OSE1001
Message Failed to boot from A.
Action
Review system boot configuration and boot media. Verify the media in a: is bootable. See
system video for additional information.
OSE1003
Message Failed to boot from C.
Action
Review system boot configuration and boot media. Verify the media in C: is bootable. See
system video for additional information.
OSE1005
Message
PXE boot failed.
Action
Review system boot configuration, local PXE configuration, and PXE server configuration.
OSE1007
Message Diagnostic boot failed.
Action
Review system boot configuration and boot media. See system video for additional
information.
OSE1009
Message Failed to boot from CD-ROM.
Action
Review system boot configuration and boot media. Verify the media in the CDROM is
bootable. See system video for additional information.
OSE1011
Message Failed to boot from ROM.
Action
Check system event logs for additional exception information. Power down the system and
attempt to boot again.
OSE1013
Message Failed to boot.
102

Advertisement

Table of Contents
loading

Table of Contents