8 Example — OPC Application for PROFIBUS-DP
8.5.2

Inserting Groups and Variables

Organizing Process Variables
The process variables of the OPC server (known as OPC items) are assigned to
groups. You therefore require an OPC group before you can insert OPC variables.
Follow the steps outlined below to create a group and add items to it:
After the OPC Server starts, a dialog opens in which you can create a group. Enter "5613_DP"
1.
as the group name and confirm your input with "OK":
2.
Double-click on the group entry "5613_DP" to open the OPC Navigator.
In the left-hand pane, you will see the hierarchically arranged name space of the OPC
variables.
3.
If you click on an element in the tree, the OPC items defined for the element appear in the
middle pane of the window: