7 External control

7.1

External input/output control

■External control connectors (12 pin × 2)
MINI COMBICON Plug 12P
(PHOENIX CONTACT: MC 1.5/12-ST-3.5)
(Osada: OS-85-12P)
Compatible wiring (stranded)
Size
AWG#24-16
Tightening torque: 0.22 to 0.25 Nm
Precautions for wiring
・ Carefully strip the cover so as not to damage the core wires.
・ Connect the core wires without twisting them.
・ Connect the core wires without soldering them; otherwise, they may break due to vibration.
・ After connection, do not apply stress to the cable.
・ Because of the terminal structure, if the wire is tightened by a counterclockwise rotation, the
connection will fail. In such cases, pull out the wire, check the terminal hole, and then connect it
again.
■Input/output terminal table
INPUT
Pin No
Signal name
1
START 1
2
START 2
3
START 3
4
START 4
5
TYPE Chg1
6
TYPE Chg2
7
TYPE Chg3
8
UV CHECK
9
STOP
10
START ALL
11
INTERLOCK
12
COM
OUTPUT
Pin No
Signal name
13
READY ALL
14
READY1/BUSY1
15
READY2/BUSY2
16
READY3/BUSY3
17
READY4/BUSY4
18
ERROR
19
ALARM
20
COM
21
COM
22
FG
23
+5V
24
COM
* Pin Nos. 12, 20, 21 and 24 are connected internally.
The ON time of input signal pulses must be 100 ms or more.
24
Conductor section area
2
0.2 - 1.25 mm
CH1 irradiation start signal
CH2 irradiation start signal
CH3 irradiation start signal
CH4 irradiation start signal
Product type switching signal
Product type switching signal
Product type switching signal
UV intensity control mode signal
Irradiation stop signal, Error reset
CH1-CH4 irradiation start signal
Interlock (normally ON)
Common terminal for input/output signals
ON when irradiation is ready to start
ON when CH1 irradiation is ready to start/in progress
ON when CH2 irradiation is ready to start/in progress
ON when CH3 irradiation is ready to start/in progress
ON when CH4 irradiation is ready to start/in progress
Error signal
Warning signal (temperature/time warning)
Common terminal for input/output signals
Common terminal for input/output signals
Frame gland
5 V DC output (for display or output signals)
Common terminal for input/output signals
Wire stripping length
6-7 mm
Description
Description
UJ35 only
READY/BUSY
singal is changed
over by changing the
initial setting mode.