(8) Multiple degree of match inspection
Using the gray search function, the IV-C35M can detect up to 128 workpieces
Purpose
whose captured image exceeds the required degree of match with the reference
Position measurement of workpieces having complicated density conditions, that
Application
could not be measured by conventional binary conversion and density processing.
Reference image
Example
[Measurement results]
- Number of images detected
- Degree of match, density (average/absolute difference), and detected coordinates
1-13
Outline
Four
workpieces
detected