Hydro Kit accessories
Table 26: Third Party Accessories (sold separately)
Hydro Kit
Accessory
Model
Hydro Kit Circuit Water
Pump Interlock
1
Solar Heating Circuit
Water Pump
Interlock
1,2,3
208-230/60/1
Conventional
Thermostat
1,4
24 VAC
Conventional
Thermostat
4
Mechanical Thermostat
1
Hydro Kit Circuit 3-Way
domestic Water divert-
ing Valve
1
Hydro Kit Circuit 2-Way
In-floor Heating
Isolation Valve
1
Solar Heating System-
Interface Kit
1
TB = Terminal Block
NO = Normally Open
NC = Normally Closed SPDT = Single Pole Double Throw
Maximum combined current draw of all connected accessories must be equal to or less than 5 Amp
1
@ 208-230/60/1.
Must have contacts rated for 208-230/60/1
2
74
Voltage
Connection
options
K3
TB-1,2
208-230/60/1
K2
TB-11,12
K2
TB-4,5
208-230/60/1
K3
TB-7,8,9,10
208-230/60/1
TB-17,18,19,20
K2
& Harness Plug
C to A
TB-17,18,19,20
K2
& Harness Plug
24 VAC
C to B
K3
TB-7,8,9,10
TB-17,18,19,20
K2
& Harness Plug
C to A
K3
TB-4,5,6
208-230/60/1
K2
TB-8,9,10
K2
TB-14,15,16
208-230/60/1
K2
TB-1,2,3
208-230/60/1
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp.
description
Hydro Kit water circuit circulating
pump interlock (use a field
provided pilot relay).
Solar heating circuit circulating pump
interlock (use a field provided
pilot relay).
Single stage heating only.
Single stage heating/cooling manual
changeover.
Single stage heat/cool, must be
manual changeover model.
Single stage manual changeover.
---
Single stage heating only.
Valve A 208-230/60/1
3-wire SPDT
Valve (A) 208-230/60/1
2 -wire NO or NC
Valve (B)208-230/60/1
3-wire SPDT
1" FPT both ends
3
Must have contacts rated for 24VAC
4
All communication cable to be minimum 18 AWG, 2-conductor, stranded, shielded, and must comply
with applicable local and national codes.
Power wiring cable is field provided and must comply with the applicable local and national codes.
Use
Provides pump ON/OFF control
based on Hydro Kit control
logic.
Provides pump ON/OFF control
based on Hydro Kit control
logic.
Monitors and/or controls (optional)
the Hydro Kit based on the
conditioned space temperature.
Monitors and/or controls (optional)
the Hydro Kit based on the
conditioned space temperature.
Monitors and/or controls (optional)
the Hydro Kit based on the
conditioned space temperature.
Diverting valve - circulates water to/
from the comfort conditioning
equipment and the Hydro Kit
water storage tank.
Partial circuit water isolation valve
prevents condensate from
forming on floors containing
in-floor heating pipe while
operating in the cooling mode.
Diverting valve circulates water
to/from the Ancillary (Solar)
Heating Interface and the
Hydro Kit heating circuit.