8.12.2 CORD HOOK
(1) Remove the two Taptite cup B M3x8 screws, and then remove the two cord hooks from
the Document scanner unit.
8.12.3 PANEL UNIT
(1) Remove the four Taptite cup B M3x10 screws.
(2) Release the Hook to remove the Panel unit from the Document scanner unit.
(3) Disconnect the connector from the Panel PCB ASSY.
Document scanner unit
Taptite cup B
M3x10
Cord hook
Fig. 3-47
<Bottom side>
Panel unit
Hook
Fig. 3-48
3-52
Document scanner unit
Cord hook
Taptite cup B M3x8
Connector
2
3
Taptite cup B M3x10
Hook
Confidential