Precautions For Fiber Connections; Installation Tool Requirements; Inspection Requirements When Unpacking The Switch; Inventory - D-Link DGS-6600 Series Hardware Installation Manual

Layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600 Series:
Table of Contents

Advertisement

DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide
4. Take appropriate measures to isolate static electricity.

Precautions for Fiber Connections

Ensure that the cables used with the Switch are of the correct optical connector type and that the fiber type
matches the optical interface type used. You should also be aware of the Tx and Rx directions of the fiber. The Tx
side of the Switch should connect to the Rx side of the switch at the remote end and the same vice versa. Also
note that only class 1 Optical Transceivers can be plugged into the SFP ports of the DGS-6600 series Modules
supporting SFP ports.

Installation Tool Requirements

The tools needed to install the switch are described in Table 2-1.:
Common Tools
Special-purpose Tools
Meters

Inspection Requirements when Unpacking the Switch

Inventory

1. DGS-6604 or DGS-6608 Chassis Carton
• DGS-6600 Series Chassis (no cards installed)
2. Card Module Carton (s)
• 1 CM Card DGS-6600-CM
• Line Cards (specific per order)
• Power Supplies Units (number specific per order)
3. DGS-6604/6608 Accessories Carton including:
• AC Power Cord
• RS-232 Console Cable (9 pin D-Sub)
• USB Console Cable (Type 1 to Type2)
• Fan Tray
• Air Filter
• CD software and manual
Cross-head screwdriver, flat-head screwdriver, required electrical and
optical cables
Bolts, diagonal pliers, straps
Anti-static tool
Multimeter
Table 2-1 Required Installation Tools