Mitsubishi Electric F700 Instruction Manual page 100

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Parameter
Name
162 to 165
Refer to Pr.57 and Pr.58.
166, 167
Refer to Pr.150 to Pr.153.
168, 169
Parameter for manufacturer setting. Do not set.
170, 171
Refer to Pr.52.
172 to 174
Refer to Pr.160.
STF terminal
178
function selection
STR terminal
179
function selection
RL terminal function
180
selection
RM terminal
181
function selection
RH terminal
182
function selection
RT terminal function
183
selection
AU terminal
184
function selection
JOG terminal
185
function selection
CS terminal
186
function selection
MRS terminal
187
function selection
STOP terminal
188
function selection
RES terminal
189
function selection
Incre
Initial
Range
ments
Value
0 to 8, 10 to
12, 14, 16,
0: Low-speed operation command (RL)
24, 25, 60,
1: Middle-speed operation command (RM)
1
60
62, 64 to 67,
2: High-speed operation command (RH)
70 to 72,
3: Second function selection (RT)
9999
4: Terminal 4 input selection (AU)
5: Jog operation selection (JOG)
0 to 8, 10 to
6: Selection of automatic restart after
12, 14, 16,
24, 25, 61,
1
61
7: External thermal relay input (OH)
62, 64 to 67,
8: Fifteen speed selection (REX)
70 to 72,
10: Inverter operation enable signal (FR-
9999
1
0
11: FR-HC, MT-HC connection,
0 to 8,
10 to 12, 14,
1
1
12: PU operation external interlock (X12)
16, 24, 25,
14: PID control valid terminal (X14)
62, 64 to 67,
1
2
16: PU-external operation switchover (X16)
70 to 72,
24: Output stop (MRS)
9999
25: Start self-holding selection (STOP)
1
3
60: Forward rotation command (STF)
0 to 8,
10 to 12, 14,
61: Reverse rotation command (STR)
1
4
16, 24, 25,
62 to 67, 70
62: Inverter reset (RES)
to 72, 9999
63: PTC thermistor input (PTC) (assigned
1
5
64: PID forward/reverse action switchover
65: PU-NET operation switchover (X65)
0 to 8,
1
6
66: External-NET operation switchover
10 to 12, 14,
16, 24, 25,
1
24
67: Command source switchover (X67)
62, 64 to 67,
70: DC feeding operation permission (X70)
70 to 72,
1
25
71: DC feeding cancel (X71)
9999
72: PID integral value reset (X72)
9999: No function
1
62
Description
instantaneous power failure (CS)
HC, MT-HC, FR-CV connection) (X10)
instantaneous power failure detection
(X11)
(assigned to STF terminal (Pr.178) only)
(assigned to STR terminal (Pr.179) only)
to AU terminal (Pr.184) only)
(X64)
(X66)
Parameter list
All
Para
Para
para
meter
meter
meter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×
×
×
×
×
4
93

Hide quick links:

Advertisement

Table of Contents
loading