Parameter
Name
Analog input
73
selection
Terminal 1 added
compensation
242
amount (terminal 2)
Terminal 1 added
compensation
243
amount (terminal 4)
Override bias
252
Override gain
253
Terminal 4 input
267
selection
Input filter time
74
constant
Reset selection/
disconnected PU
75
detection/PU stop
selection
Fault code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Incre
Initial
Range
ments
Value
You can select the input specifications of
terminal 2 (0 to 5V, 0 to 10V, 0 to 20mA)
and input specifications of terminal 1 (0 to
±5V, 0 to ±10V).
To change the terminal 2 to the voltage
0 to 7,
1
1
input specification (0 to 5V/ 0 to 10V), turn
10 to 17
OFF(initial status) the voltage/current input
switch 2. To change it to the current input(0
to 20mA), turn ON the voltage/current input
switch 2. Override and reversible operation
can be selected.
Set the ratio of added compensation
0.1%
100%
0 to 100%
amount when terminal 2 is the main speed.
Set the ratio of added compensation
0.1%
75%
0 to 100%
amount when terminal 4 is the main speed.
Set the bias side compensation value of
0.1%
50%
0 to 200%
override function.
Set the gain side compensation value of
0.1%
150%
0 to 200%
override function.
Terminal 4 input 4 to
0
20mA
1
0
Terminal 4 input 0 to
1
5V
Terminal 4 input 0 to
2
10V
The primary delay filter time constant for
1
1
0 to 8
the analog input can be set.
A larger setting results in slower response.
You can select the reset input acceptance,
disconnected PU (FR-DU07
PU07
0 to 3,
1
14
PU stop function.
14 to 17
For the initial value, reset always enabled,
without disconnected PU detection, and
with PU stop function are set.
0
Without fault code output
1
0
1
With fault code output
2
Fault code output at fault occurrence only
0
Write is enabled only during a stop
1
0
1
Parameter write is disabled.
Parameter write is enabled in any operation
2
mode regardless of operating status.
0
Both forward and reverse rotations allowed
1
0
1
Reverse rotation disallowed
2
Forward rotation disallowed
Description
Turn ON the
voltage/current
input switch 1 (initial
status).
Turn OFF the
voltage/current
input switch 1.
/FR-PU04/FR-
) connector detection function and
Parameter list
All
Para
Para
para
meter
meter
meter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
4
85