Memory Back-Up Switch; Explanation To Customers - Sanyo SHA TM64 AGB Instruction Manual

Control system for spw air conditioner system
Table of Contents

Advertisement

Schedule Timer
(4) To continue registering addresses, repeat step (3). (Central control address numbers will be added to the right side of the
LCD display.) To cancel a registered central control address, use the
then use the
(5) Repeat steps (3) - (4) for each timer group. When registration is completed, press the timer
timer restarts automatically and performs initial communications. (SCAn blinks in the display.) The normal display appears
after several minutes, and the manually assigned timer group settings are confi rmed.

Memory Back-Up Switch

After installation is completed, check that the backup switch on the reverse side of the schedule timer PCB is turned to ON.
(The backup battery will retain the current time for up to 100 hours.)
OFF
ON
Checking the Central Control Addresses and Operating the Units that are Controlled by the Schedule
Timer
The schedule timer communicates with the indoor units to check which central control addresses can be controlled with the cur-
rent timer control. The schedule timer can then be used to start and stop these units.
(1) Press and hold the schedule timer
3
control address)" appears in sequence, blinking.
(2) Use the GROUP button in the
possible to check which central control addresses in the displayed timer group can be operated by the timer.
(3) With the selected timer group displayed, press the timer
in the displayed timer group start or stop. Pressing the
operation mode, temperature setting items) at the indoor units in the displayed timer group where remote controller prohibit
is in effect.
(4) After checking the addresses and operating the units, press and hold the
ule timer display returns to the normal display and all controllable indoor units stop.

Explanation to Customers

After work is completed, present the Operation Manual and Information for the Person in Charge of Installation (Electrical)
Work to the customer.
Explain to the customer the methods for use of the system, as described in the Operation Manual.
button in the
area to select the central control address and press the
Backup switch
Backup battery
button,
area to display the blinking central control addresses in sequential order. In this way, it is
.
button in the
button, and CLEAR button for 4 seconds or longer. "Ad-(central
button. Each time the button is pressed the indoor units
button in this mode permits all items (operation start/stop,
button for 2 seconds or longer. The sched-
area to select the timer group,
button.
button. The schedule

Hide quick links: