CONVERSION TO NATURAL GAS OR TO LPG
REPLACEMENT OF THE INJEC-
TORS OF THE TOP BURNERS
If the injectors are not supplied they can
be obtained from the After-Sales Service.
Select the injectors to be replaced accor-
ding to the "Table for the choice of the in-
jectors".
To replace the injectors proceed as fol-
lows:
Remove pan supports and burners
from the cooktop.
Using a wrench, substitute the nozzle
injectors "J" (figs. 10.4, 10.5) with tho-
se most suitable for the kind of gas for
which it is to be used.
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
ADJUSTING OF THE MINIMUM OF
THE TOP BURNERS
In the minimum position the flame must
have a length of about 4 mm and must re-
main lit even with a quick turn from the ma-
ximum position to that of minimum.
The flame adjustment is done in the fol-
lowing way:
Turn on the burner.
Turn the tap to the MINIMUM position.
Take off the knob.
With a thin screwdriver turn the screw
"F" until adjustment is correct (fig.
10.6).
Normally for LPG, tighten up the regu-
lation screw.
34
Auxiliary,
Semi-rapid and
Rapid burners
Fig. 10.4
Triple-ring burner
Fig. 10.5
F
Fig. 10.6