ELECTRICAL FEEDER CABLE CONNECTION
The operations must be executed by a qualified technician.
To connect the supply cable:
Remove the screws securing the cover "
Feed the supply cable through the cable clamp "
be of a suitable size for the current requirements of the appliance; see the section
"Feeder cable section".
Connect the wires to the terminal block "
connect the phase and neutral wires to the terminal block "B" and the earth wire to the
terminal "PE" as shown in figure 11.2.
Take up any slack in the cable and secure with the cable clamp "
Replace the cover "
N.B. The earth conductor must be left about 3 cm longer than the others.
FEEDER CABLE SPECIFICATIONS
TYPE H05RR-F
230 V AC
3 X 0,75 mm
B
A
Fig. 11.2
A".
2
PE
N
D
L
A" on the rear of the cooker (fig. 11.2).
D" (fig. 11.2). The supply cable must
B" as shown in the diagram in figure 11.3; or
230
L
1
Fig. 11.3
D".
N
PE
(L
)