Error Code
Message Information
Details
Action
BAT0002
Message
Details
Action
BAT0017
Message
Details
Action
CPU0000
Message
Details
Action
CPU0001
Message
Details
Action
CPU0005
Message
Details
Action
CPU0010
Message
Details
Action
70
The operating system or an application failed to
communicate within the time-out period. The system was
power-cycled.
Check the operating system, application, hardware, and
system event log for exception events.
The system board battery has failed.
The system board battery is either missing or bad.
See
Getting
Help.
The <name> battery has failed.
The <name> battery is either missing, bad, or unable to
charge due to thermal issues.
Check system fans. If the problem persists, see
CPU <number> has an internal error (IERR).
System Event Log and Operating System Logs may indicate
that the exception is external to the processor.
Review System Event Log and Operating System Logs. If the
issue persists, see
Getting
CPU <number> has a thermal trip (over-temperature) event.
The processor temperature increased beyond the
operational range.
Review the logs for fan failures. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see
CPU <number> configuration is unsupported.
System is unable to boot or may run in a degraded state.
Review the technical specifications for supported processor
types.
CPU <number> is throttled.
The CPU is throttled due to thermal or power conditions.
Review system logs for power or thermal exceptions.
Getting
Help.
Getting
Help.
Help.