Kenwood NXR-710 Service Manual page 42

Vhf digital base-repeater
Hide thumbs Also See for NXR-710:
Table of Contents

Advertisement

NXR-710
Item
Condition
5. Sensitivity 2
FPU Test mode
Adjust
1) Adjust Item: [Sensitivity 2]
BPF Adjust
2) Adjust Item: [Low], [Low'],
[Center], [High'], [High]
6. AGC Target
FPU Test mode
Level adjust
1) Adjust Item: [AGC Target
Level Adjustment]
7. AGC adjust-
FPU Test mode
ment
1) Adjust Item: [AGC Adjust-
[Analog Nar-
ment (Analog Narrow)]
row]
2) Adjust Item: [Low], [Low'],
[Center], [High'], [High]
8. AGC adjust-
FPU Test mode
ment
1) Adjust Item: [AGC Adjust-
[Analog
ment (Analog Wide)]
Wide]
2) Adjust Item: [Low], [Low'],
[Center], [High'], [High]
9. AGC adjust-
FPU Test mode
ment
1) Adjust Item: [AGC Adjust-
[NXDN Very
ment (NXDN Very Narrow)]
Narrow]
2) Adjust Item: [Low], [Low'],
[Center], [High'], [High]
10. Frequency
FPU Test mode
Adjust
1) Adjust Item: [Frequency]
Connect the SSG to the RX
ANT.
CH: 1 (Analog Narrow)
SSG Output: –47dBm (1mV)
(CW (without modulation))
Caution:
Perform the frequency adjust-
ment under the following condi-
tion.
• Temperature range of
+23°C to +27°C (+73.4°F to
+80.6°F).
(The temperature is displayed
on the frequency adjustment
screen of the KPG-129D.)
• Use an accuracy of 0.003ppm
for the SSG.
(Use a standard oscillator if
necessary.)
42
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
RX ANT
Adjustment
Parts
Method
PC
Write the value as
Press [Apply All] button to
ADJ
followings (typical
store the adjustment value.
value)
[Low] = 65
Variable-Capacitor Tune volt-
[Low'] = 75
age is adjusted.
[Center] = 90
(Output voltage is adjustment
[High'] = 115
of BPF)
[High] = 145
Write the value as
Press [Apply] button to store
followings (typical
the adjustment value.
value)
[AGC Target Level
Adjustment] = –18
Write the value as
Press [Apply All] button to
followings (typical
store the adjustment value.
value)
[Low] = 256
[Low'] = 256
[Center] = 256
[High'] = 256
[High] = 256
PC
Press [Start] button of [Auto
ADJ
Tuning].
Press [Apply] Button to store
the adjustment value after the
automatic adjustment was
fi nished.
Specifi cations / Remarks