Kenwood NXR-710 Service Manual page 48

Vhf digital base-repeater
Hide thumbs Also See for NXR-710:
Table of Contents

Advertisement

NXR-710
Item
Condition
9. Balance
FPU Test mode
Adjust
1) Adjust Item: [Balance]
[20Hz Ad-
Connect the Deviation Meter
justment]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz
HPF: OFF
De-emphasis: OFF
2) Adjust Item: [A: Low],
[A: Center], [A: High],
[B: Low], [B: Center],
[B: High]
Press [Transmit] button.
20Hz is transmitted.
[2.0kHz
FPU Test mode
Adjustment]
1) Adjust Item: [Balance]
[2kHz Sine Wave] check box
is checked.
2) Adjust Item: [A: Low],
[A: Center], [A: High],
[B: Low], [B: Center],
[B: High]
Press [Transmit] button.
Check while transmitting
change to 2kHz.
10. Standard
1) Connect the Deviation Meter
Modulation
to the TX ANT end via the ATT.
Check
Deviation Meter setting
[Analog
LPF: 15kHz
Wide ]
HPF: OFF
De-emphasis: OFF
Detector: (p-p)/2
2) Connect the AG to the MIC
Terminal of MIC connector.
AG Frequency
: 1kHz (Sine Wave)
AG Output level: Adjust to
become the 3kHz Deviation.
[Analog Nar-
1) Connect the Deviation Meter
row ]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Detector: (p-p)/2
2) Connect the AG to the MIC
Terminal of MIC connector.
AG Frequency
: 1kHz (Sine Wave)
AG Output level: Adjust to
become the 1.5kHz Deviation.
48
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Oscilloscope
Deviation
Rear
TX ANT
meter
Oscilloscope
Front
MIC
AG
DVM
Adjustment
Parts
Method
PC
The Deviation of
2kHz Tone deviation is within
ADJ
20Hz frequency is
±1.0% of 20Hz tone devia-
fi xed to 2.05kHz
tion.
Deviation.
Change the 2kHz
Press [Apply All] button to
adjustment value to
store the adjustment value
become the same
after all adjustment point was
deviation to 20Hz
adjusted.
within the specifi ed
range.
Check
5.0mV±1.5mV
Specifi cations / Remarks