NXR-710
Item
Condition
6. Open
FPU Test mode
Squelch
1) Adjust Item: [Open Squelch
Adjust
(Analog Narrow)]
[Analog Nar-
Connect the SSG to the RX
row]
ANT.
SSG setting
Frequency: [Low], [Low'],
[Center], [High'], [High]
Output
: 12dB SINAD level –1dB
MOD: 1.0kHz
DEV: ±1.5kHz
2) SSG output: OFF
7. Open
FPU Test mode
Squelch
1) Adjust Item: [Open Squelch
Adjust
(NXDN Very Narrow)]
[NXDN Very
Connect the SSG to the RX
Narrow]
ANT.
SSG setting
Frequency: [Low], [Low'],
[Center], [High'], [High]
Output: 12dB SINAD level
of Analog Narrow –4dB
MOD: OFF
8. Tight
FPU Test mode
Squelch
1) Adjust Item: [Tight Squelch
Adjust
(Analog Wide)]
[Analog
Connect the SSG to the RX
Wide]
ANT.
SSG setting
Frequency: [Low], [Low'],
[Center], [High'], [High]
Output
: 12dB SINAD level +6dB
MOD: 1.0kHz
DEV: ±3.0kHz
2) SSG output: OFF
9. Tight
FPU Test mode
Squelch
1) Adjust Item [Tight Squelch
Adjust
(Analog Narrow)]
[Analog Nar-
Connect the SSG to the RX
row]
ANT.
SSG setting
Frequency: [Low], [Low'],
[Center], [High'], [High]
Output
: 12dB SINAD level +8dB
MOD: 1.0kHz
DEV: ±1.5kHz
2) SSG output: OFF
44
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
RX ANT
Audio
analyzer
Oscilloscope
Adjustment
Parts
Method
PC
Press [Apply] button to store
ADJ
the adjustment value.
Note:
Write the fi xed value of "30"
when the adjustment value is
24 or less.
Check
The squelch shall be closed.
PC
Press [Apply] button to store
ADJ
the adjustment value.
PC
Press [Apply] button to store
ADJ
the adjustment value.
Check
The squelch shall be closed.
PC
Press [Apply] button to store
ADJ
the adjustment value.
Check
The squelch shall be closed.
Specifi cations / Remarks