Kenwood NXR-710 Service Manual page 45

Vhf digital base-repeater
Hide thumbs Also See for NXR-710:
Table of Contents

Advertisement

Item
Condition
10. RSSI
FPU Test mode
Refarence
1) Adjust Item [RSSI Ref (Analog
Adjust
Wide)]
[Analog
Connect the SSG to the RX
Wide]
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output
: 12dB SINAD level –1dB
MOD: 1.0kHz
DEV: ±3.0kHz
11. RSSI
FPU Test mode
Refarence
1) Adjust Item [RSSI Ref (Analog
Adjust
Narrow)]
[Analog Nar-
Connect the SSG to the RX
row]
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output
: 12dB SINAD level –1dB
MOD: 1.0kHz
DEV: ±1.5kHz
12. RSSI
FPU Test mode
Refarence
1) Adjust Item [RSSI Ref (NXDN
Adjust
Very Narrow)]
[NXDN Very
Connect the SSG to the RX
Narrow]
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output
: 12dB SINAD level –1dB
MOD: OFF
13. Low RSSI
FPU Test mode
Adjust
1) Adjust Item [Low RSSI (Ana-
[Analog
log Wide)]
Wide]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output: –118dBm (0.28µV)
MOD: 1.0kHz
DEV: ±3.0kHz
14. Low RSSI
FPU Test mode
Adjust
1) Adjust Item [Low RSSI (Ana-
[Analog Nar-
log Narrow)]
row]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low']
[Center], [High'], [High]
Output: –118dBm (0.28µV)
MOD: 1.0kHz
DEV: ±1.5kHz
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
RX ANT
Audio
analyzer
SSG
Rear
RX ANT
NXR-710
Adjustment
Parts
Method
PC
Press [Apply] button to store
ADJ
the adjustment value.
PC
Press [Apply] button to store
ADJ
the adjustment value.
Specifi cations / Remarks
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents