Modification; Disassembly For Repair; Dc Source Switch; How To Remove The Panel Assy (Abs) - Kenwood NXR-710 Service Manual

Vhf digital base-repeater
Hide thumbs Also See for NXR-710:
Table of Contents

Advertisement

NXR-710

1. DC Source Switch

To prevent the power supply from turning off due to
misoperation of the DC source switch on the front panel or
accidents (tampering) after installation, the main unit can be
kept on regardless of the on/off setting of the DC source
switch on the front panel.
Using solder, short the PSW land near the CN40 connec-
tor.

1. How to Remove the Panel Assy (ABS)

Note: You can remove the panel assembly (ABS) without
removing the top panel (A62-1148-03).
1. To remove the panel (TX-RX, w ), loosen the 6 screws
( q ).
2. To remove the panel assembly (Front, r ), loosen the 6
screws ( e ).
3. The panel assembly (ABS) is securely fastened by 4 tabs
( t ) on the top and bottom. You can remove the panel
assembly by pulling to the front while you are pulling up
the tabs.
8