Kenwood NXR-710 Service Manual page 49

Vhf digital base-repeater
Hide thumbs Also See for NXR-710:
Table of Contents

Advertisement

Item
Condition
11. TD Devia-
FPU Test mode
tion adjust
1) Adjust Item: [TD Deviation
[Analog
(Analog Wide)]
Wide]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
2) Connect the AG to the TD
Terminal of Control I/O Jack.
AG Frequency
: 100Hz (Sine Wave)
AG Output level
: 0.5Vpp (177mVrms)
Press [Transmit] button.
12. TD Devia-
FPU Test mode
tion adjust
1) Adjust Item: [TD Deviation
[Analog Nar-
(Analog Narrow)]
row]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
2) Connect the AG to the TD
Terminal of Control I/O Jack.
AG Frequency
: 100Hz (Sine Wave)
AG Output level
: 0.5Vpp (177mVrms)
Press [Transmit] button.
13. Transmit
FPU Test mode
Audio Input
1) Adjust Item: [Transmit Audio
(TA) adjust
Input (TA) (Analog Wide)]
Connect the Deviation Meter
[Analog
Wide]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz, HPF: OFF
De-emphasis: OFF
2) Connect the AG to the TA
Terminal of Control I/O Jack.
AG Frequency
: 1kHz (Sine Wave)
AG Output level: 280mVrms
Press [Transmit] button.
14. Transmit
FPU Test mode
Audio Input
1) Adjust Item: [Transmit Audio
(TA) adjust
Input (TA) (Analog Narrow)]
[Analog Nar-
Connect the Deviation Meter
row]
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz, HPF: OFF
De-emphasis: OFF
2) Connect the AG to the TA
Terminal of Control I/O Jack.
AG Frequency
: 1kHz (Sine Wave)
AG Output level: 280mVrms
Press [Transmit] button.
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Oscilloscope
AG
Control
AF VTVM
I/O Jack
TD (Pin
No.8)
Deviation
Rear
TX ANT
meter
Oscilloscope
AG
Control
AF VTVM
I/O Jack
TA (Pin
No.9)
NXR-710
Adjustment
Parts
Method
PC
0.75kHz Deviation
±0.1kHz
ADJ
Press [Apply] button to store
the adjustment value.
PC
3.0kHz Deviation
±0.1kHz
ADJ
Press [Apply] button to store
the adjustment value.
1.5kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
Specifi cations / Remarks